Chapter 2 PRECAUTION
2-9
NWA-033623-001 Rev.8.1
91ch2001.fm
PASSWORD ENTRY
PASSWORD ENTRY
In a system with password service, a maintenance person is required to enter an authorization level number
(Password Level) and appropriate password prior to engaging in programming the system data with the
PCPro/CAT. A maximum of eight (8) Password Levels can be set up. The number of commands that the
maintenance person can access is determined by the Password Level.
Password and accessible commands for each Password Level is determined by system data.
The procedure for programming, with password, is shown below.
STEP1:
Connect the PCPro to the system, and turn the power switch on.
For the CAT, change the mode to CAT.
STEP2:
Enter the password (assigned by CME9>0-7) by CM03.
Operation:
– “OK” will be displayed, if accepted.
In case of “DATA ERROR”, the password is incorrect.
STEP3:
Start programming.
STEP4:
When programming is completed, set the following data by CM03.
Operation:
– Programming without password is restricted.
NOTE:
For the details of data assignment for password service, refer to CME7, CME9 on Chapter 3
Command Description.
+ 03 +
+ Password Level No. +
+ Pa
ST
EXE
DE
DE
+ 03 +
+ 9 +
+ CC
8 digits
EXE
ST
DE
DE
JULY/17/2009
Содержание SV8300
Страница 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Страница 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Страница 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...