3-318
NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE TITLE:
TRUNK ROUTE DATA
35
: Default
Y
SETTING DATA
RELATED
COMMAND
No.
MEANING
DATA
MEANING
290
Setting of PAD data from a
station to a trunk
01
15
16
17
31
NONE
-15 dB
(1 dB increment)
-1 dB
0 dB
+1 dB
(1 dB increment)
+15 dB
0 dB
+: Gain
- : Loss
NOTE:
This command is effective for the following trunks.
- LDT/ODT/PRT/DTI/CCT/SIP/IPT (P2P CCIS)
291
CODEC Filter Type
00
01
02
03
15
Not filtered
TYPE1 (Very short distance)
TYPE2 (Middle distance)
TYPE3 (Long distance)
TYPE2 (Middle distance)
NOTE 1:
This command is effective for the data set for the trunk route of the base port of each COT/LDT/ODT
blade (All ports of the blade including COTDB become the same setting).
NOTE 2:
For the second data, signal losses in the line distance of the line are estimated as follows.
Second data: 01 (TYPE1 [Very short distance])........ 0 dB
: 02 (TYPE2 [Middle distance]) ............. 4 dB
: 03 (TYPE3 [Long distance]) ................ 8 dB
NOTE 3:
For a COT blade, set the second data shown below depending on the line distance of the ordinary line.
- Set the second data to “01” (TYPE1 [Very short distance]) when connecting to the behind PBX, TA
and IP terminal adapter.
- Set the second data to “03” (TYPE3 [Long distance]) when the line is far from the Office PBX and
the signal attenuation is heavily.
NOTE 4:
For a LDT/ODT blade, set the second data depending on the line distance of the line.
Continued on next page
~
~
~
~
BLADE RESET
JUNE/15/2011
CM35
Содержание SV8300
Страница 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Страница 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Страница 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...