3-137
NWA-033623-001 Rev.8.1
91ch3001.fm
COMMAND CODE TITLE:
UPDATING OF IP STATION FIRMWARE/REMOTE SYSTEM
UPGRADE
0C
: Default
Y
1ST DATA
2ND DATA
No.
MEANING
DATA
MEANING
DATA
MEANING
53
System Upgrade
(Stand by CPU)
[8300R4]
0101
Changeover
(changeback)
time
YYYY MM
DD HH mm
000000000000
CCC
NONE
YYYY: Year (2011-2099)
MM
: Month (01-12)
DD
: Date (01-31)
HH
: Hour (00-23)
mm
: Minutes (00-59)
Executed immediately
Clear
No data
NOTE 1:
If a specified changeover time is passed while CPU program is being download-
ed, the changeover of CPU program is executed immediately (second data be-
comes 000000000000).
NOTE 2:
If you set the second data to 000000000000 while CPU program is being down-
loaded, the CPU program changeover is executed after CPU program download
is completed.
NOTE 3:
This data is cleared after CPU program changeover is completed.
NOTE 4:
If the system is reset five times during about three minutes, the CPU program
changeback is executed automatically.
NOTE 5:
When the communication between Active CPU and Stand by CPU cannot oper-
ate normally, “HARDWARE ERROR” is displayed.
Continued on next page
JANUARY/31/2012
CM0C
Содержание SV8300
Страница 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Страница 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Страница 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...