3-687
NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE TITLE:
MAINTENANCE BY PCPro/CAT
EC
System Data Backup
NOTE 6:
You can assign only “0” to the second data. “1” is displayed while the system data is being
copied.
NOTE 7:
Backup takes about 5 minutes on On-line/Off-line mode. While saving the system data to flash
memory, “SYSD” LED on the CPU blade flashes.
NOTE 8:
Do not turn off or reset the system while “SYSD” LED on the CPU blade is flashing.
SDRAM Data Clear
NOTE 9:
Execute the system data backup by CMEC Y=6>0: 0 after this data clear.
Y
1ST DATA
2ND DATA
RELATED
COMMAND
No.
MEANING
DATA
MEANING
DATA
MEANING
6
System data
backup
0
System data backup
0
1
3
Start to save
Now saving
Stand by
NOTE 6
CM43 Y=5
Y
1ST DATA
2ND DATA
RELATED
COMMAND
No.
MEANING
DATA
MEANING
DATA
MEANING
7
SDRAM Data
Clear
00
ID registration for
IP Station in Auto-
matic Login Mode
all clear
CCC
Clear
NOTE 9
OFF LINE
APRIL/16/2010
CMEC