slot
location
type
assign port
condition
note
10
3–2
-none-
-none-
Not Install
Slot 10 : Information of EXIFE2 (Slot
2 : 408E/008E/000E)
11
3–3
008E
-none-
Running
Slot 11 : Information of EXIFE2 (Slot
3 : 408E/008E/000E)
HBIU
33–40
Running
Slot 11 : Information of EXIFE2 (Slot
3 : 008E : SLOT (HBI))
-none-
-none-
Not Install
Slot 11 : Information of EXIFE2 (Slot
3 : 008E : SLOT2 (HBI))
*1
12
3–4
-none-
-none-
Not Install
Slot 12 : Information of EXIFE2 (Slot
4 : 408E/008E/000E)
10
3–2
BRIU
21–24
Running
Slot 10 : Information of EXIFE2 (Slot
2 : BRI/PR)
11
3–3
-none-
-none-
Not Install
Slot 11 : Information of EXIFE2 (Slot
3 : BRI/PRI)
12
3–4
-none-
-none-
Not Install
Slot 12 : Information of EXIFE2 (Slot
4 : BRI/PRI)
13
4–1
408M
-none-
Running
Slot 13 : Information of EXIFE3
(408M)
-none-
-none-
Not Install
Slot 13 : Information of EXIFE3
(408M : SUB SLOT (COI))
*4
HBIU
41–48
Running
Slot 13 : Information of EXIFE3
(408M : SUB SLOT (HBI))
-none-
-none-
Not Install
Slot 13 : Information of EXIFE3
(408M : SUB SLOT (HBI))
*1
14
4–2
-none-
-none-
Not Install
Slot 14 : Information of EXIFE3 (Slot
2 : 408E/008E/000E)
15
4–3
-none-
-none-
Not Install
Slot 15 : Information of EXIFE3 (Slot
3 : 408E/008E/000E)
16
4–4
-none-
-none-
Not Install
Slot 16 : Information of EXIFE3 (Slot
4 : 408E/008E/000E)
1. HBIU control both SLT and KST in same pakage. It will show both information but since it shows same
information one of page will show as “none”.
2. Shows 000E as “-none-”.
3. Shows 408M/408E/008E and PRI/BRI as different output.
4. COIU of Expansion3 has a restriction and it will show as “-none-”.
Conditions
•
Alarm Reports and System Information Reports can be output to a CF card on the CPU.
•
The SL1000 supports the following Alarms to be output to the LCD of a multiline terminal:
- SMDR Buffer Full
- CPU-LAN link Error
•
The SL1000 does not support printouts of the following Alarms:
- Power Failure
- RAM Backup Battery Error
- Networking Keep Alive Error
•
Up to 12 System Alarm times can be scheduled to print on a Monthly, Daily, and Hourly time frame.
The report indicates both Major and Minor Alarms.
•
System Information Reports cannot be set to output at a scheduled time.
•
When using the E-mail functionality of reports, the E-mail address in Program 90-11-10 (From Ad-
dress) must be set for the E-mail feature to work.
•
After a new alarm is output, it cannot be output a second time.New alarms must be generated before
Program 90-12-04 can be performed a second time.
ISSUE 1.0
SL1000
A
Alarm Reports
1-24
Содержание SL1000
Страница 1: ...Features and Specifications Manual A50 031169 001 ISSUE 1 0 January 2011 ...
Страница 41: ...Operation None ISSUE 1 0 SL1000 A Features and Specifications Manual 1 33 ...
Страница 57: ...Operation None ISSUE 1 0 SL1000 B Features and Specifications Manual 1 49 ...
Страница 95: ...Operation None ISSUE 1 0 SL1000 C Features and Specifications Manual 1 87 ...
Страница 154: ...Operation None ISSUE 1 0 SL1000 D Data Line Security 1 146 ...
Страница 279: ...Figure 1 20 Cascade Message Notification Flow Chart 1 ISSUE 1 0 SL1000 I Features and Specifications Manual 1 271 ...
Страница 280: ...Figure 1 21 Cascade Message Notification Flow Chart 2 ISSUE 1 0 SL1000 I InMail Cascade Message Notification 1 272 ...
Страница 324: ...Operation LCR Operation Flow Diagram ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 316 ...
Страница 325: ...LCR Dial LCR Dial Editing ISSUE 1 0 SL1000 L Features and Specifications Manual 1 317 ...
Страница 326: ...LCR Cost Centre Code ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 318 ...
Страница 586: ...Memo ISSUE 1 0 SL1000 Features Availability by Software Revision 3 6 ...
Страница 587: ...Memo ISSUE 1 0 SL1000 Features and Specifications Manual 3 7 ...
Страница 588: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...