Program Number
Program Name
Default
45-05-09
Voice Mail Send Protocol Signal Without Additional
Digits - Clear Down String
0
80-03-01
DTMF Tone Receiver Setup - Detect Level
Type 1~5 = 0
80-03-02
DTMF Tone Receiver Setup - Start delay time
Type 1~5 = 0
80-03-03
DTMF Tone Receiver Setup - Min. detect level
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3 = 10 (-20dBm)
Type 4 = 10 (-20dBm)
Type 5 = 10 (-20dBm)
80-03-04
DTMF Tone Receiver Setup - Max. detect level
2 (-2dBm)
80-03-05
DTMF Tone Receiver Setup - Forward twist level
Type 1~5 = 5 (6dBm)
80-03-06
DTMF Tone Receiver Setup - Backward twist level
Type 1~5 = 0 (1dBm)
80-03-07
DTMF Tone Receiver Setup - ON detect time
Type 1~5 = 1 (30ms)
80-03-08
DTMF Tone Receiver Setup - OFF detect time
Type 1~5 = 1 (30ms)
80-04-01
Call Progress Tone Detector Setup - Detection Level
Type 1 (DT) = 0 (-25dBm)
Type 2 (BT) = 0 (-25dBm)
Type 3 (RBT) = 0 (-25dBm)
Type 4 = 0
Type 5 = 0
80-04-02
Call Progress Tone Detector Setup - Min. Detection
Level
0~15
Type 1 (DT) = 15 (-25dBm)
Type 2 (BT) = 15 (-25dBm)
Type 3 (RBT) = 15 (-25dBm)
Type 4 = 0
Type 5 = 0
80-04-03
Call Progress Tone Detector Setup - S/N Ratio
Type 1 (DT) = 4 (-20dB)
Type 2 (BT) = 4 (-20dB)
Type 3 (RBT) = 4 (-20dB)
Type 4 = 0
Type 5 = 0
80-04-04
Call Progress Tone Detector Setup - No Tone Time
Type 1 (DT) = 132 (3990ms)
Type 2 (BT) = 132 (3990ms)
Type 3 (RBT) = 132 (3990ms)
Type 4 = 0
Type 5 = 0
80-04-05
Call Progress Tone Detector Setup - Pulse Count
Type 1 (DT) = 1
Type 2 (BT) = 1
Type 3 (RBT) = 1
Type 4 = 0
Type 5 = 0
80-04-06
Call Progress Tone Detector Setup - ON minimum time
Type 1 (DT) = 63 (1920ms)
Type 2 (BT) = 12 (390ms)
Type 3 (RBT) = 25 (780ms)
Type 4 = 0
Type 5 = 0
80-04-07
Call Progress Tone Detector Setup - ON maximum time
Type 1 (DT) = 0
Type 2 (BT) = 20 (630ms)
Type 3 (RBT) = 40 1230ms)
Type 4 = 0
Type 5 = 0
80-04-08
Call Progress Tone Detector Setup - OFF minimum time
Type 1 (DT) = 1 (60ms)
Type 2 (BT) = 12 (390ms)
Type 3 (RBT) = 52 (1590ms)
Type 4 = 0
Type 5 = 0
80-04-09
Call Progress Tone Detector Setup - OFF maximum
time
Type 1 (DT) = 1 (60ms)
Type 2 (BT) = 14 (450ms)
Type 3 (RBT) = 80 (2430ms)
Type 4 = 0
Type 5 = 0
ISSUE 1.0
SL1000
V
Voice Mail Integration (Analog)
1-526
Содержание SL1000
Страница 1: ...Features and Specifications Manual A50 031169 001 ISSUE 1 0 January 2011 ...
Страница 41: ...Operation None ISSUE 1 0 SL1000 A Features and Specifications Manual 1 33 ...
Страница 57: ...Operation None ISSUE 1 0 SL1000 B Features and Specifications Manual 1 49 ...
Страница 95: ...Operation None ISSUE 1 0 SL1000 C Features and Specifications Manual 1 87 ...
Страница 154: ...Operation None ISSUE 1 0 SL1000 D Data Line Security 1 146 ...
Страница 279: ...Figure 1 20 Cascade Message Notification Flow Chart 1 ISSUE 1 0 SL1000 I Features and Specifications Manual 1 271 ...
Страница 280: ...Figure 1 21 Cascade Message Notification Flow Chart 2 ISSUE 1 0 SL1000 I InMail Cascade Message Notification 1 272 ...
Страница 324: ...Operation LCR Operation Flow Diagram ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 316 ...
Страница 325: ...LCR Dial LCR Dial Editing ISSUE 1 0 SL1000 L Features and Specifications Manual 1 317 ...
Страница 326: ...LCR Cost Centre Code ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 318 ...