Program
Number
Program Name
Default
14-01-05
Basic Trunk Data Setup - Receive Gain Level for Conference
and Transfer Calls
16 (-8dB)
14-02-09
Analog Trunk Data Setup - Busy Tone Detection
0
20-13-46
Class of Service Options (Supplementary Service) - Remote
Conference
COS 01~15 = 1
20-34-01
Remote Conference Group Setup - Conference Name
Group1 - Conf 1
Group2 - Conf 2
Group3 - Conf 3
Group4 - Conf 4
20-34-02
Remote Conference Group Setup - Password
Group1 - 1111
Group2 - 2222
Group3 - 3333
Group4 - 4444
20-34-03
Remote Conference Group Setup - Maximum Participants
8
20-34-04
Remote Conference Group Setup - Maximum Conference
Duration
7200
20-34-05
Remote Conference Group Setup - End Tone Alert Time
300
Operation
To joining a Remote Conference Call:
1. Internal Extension: Lift the handset and dial the extension number of the Remote Conference pilot
number (assigned in Program 11-19-01).
- OR -
1. External Party:
Dial the telephone number for the Remote Conference pilot number(assigned in Program 11-19-
01).
•
When using a subaddress, dial the Remote Conference pilot number as the Subaddress
2. The password is requested by the VRS (Password please).
3. Dial the password of the conference group.
4. If the password matches, the participant becomes part of the Remote Conference.
If the password does not match, a warning tone is heard.
•
A busy tone will also be heard if the maximum number of Remote Conference participants has
been reached or if a conference resource cannot be secured.
•
As the maximum time for the conference nears, the system will provide an end tone to the par-
ticipants according to the timer in Program 20-34-05. Once this timer expires, if the conference is
still ongoing, the call will be disconnected by the system.
ISSUE 1.0
SL1000
C
Conference, Remote
1-140
Содержание SL1000
Страница 1: ...Features and Specifications Manual A50 031169 001 ISSUE 1 0 January 2011 ...
Страница 41: ...Operation None ISSUE 1 0 SL1000 A Features and Specifications Manual 1 33 ...
Страница 57: ...Operation None ISSUE 1 0 SL1000 B Features and Specifications Manual 1 49 ...
Страница 95: ...Operation None ISSUE 1 0 SL1000 C Features and Specifications Manual 1 87 ...
Страница 154: ...Operation None ISSUE 1 0 SL1000 D Data Line Security 1 146 ...
Страница 279: ...Figure 1 20 Cascade Message Notification Flow Chart 1 ISSUE 1 0 SL1000 I Features and Specifications Manual 1 271 ...
Страница 280: ...Figure 1 21 Cascade Message Notification Flow Chart 2 ISSUE 1 0 SL1000 I InMail Cascade Message Notification 1 272 ...
Страница 324: ...Operation LCR Operation Flow Diagram ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 316 ...
Страница 325: ...LCR Dial LCR Dial Editing ISSUE 1 0 SL1000 L Features and Specifications Manual 1 317 ...
Страница 326: ...LCR Cost Centre Code ISSUE 1 0 SL1000 L LCR Least Cost Routing 1 318 ...
Страница 586: ...Memo ISSUE 1 0 SL1000 Features Availability by Software Revision 3 6 ...
Страница 587: ...Memo ISSUE 1 0 SL1000 Features and Specifications Manual 3 7 ...
Страница 588: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...