CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 123
(2)
At Called Station
At the called station, the
telephone does not ring.
(1) “ON” lamp on the PWR card is on.
(2) Volume Control of the telephone
set.
(1) LC card
(2) Telephone set
(3) PWR card (In case all station fails
within same PIM.)
The call is routed to a station
other than the dialed number.
(1) System Data Programming for
destination station Number: CM10
(2) Call Forwarding-All Calls feature is
activated at the destination station.
Ringing Signal is not
disconnected after going off-
hook.
(1) LC card
(2) FP card
(3) MP card
(4) Telephone set
START
END
CHECK