NEAX2000
IVS
2
Maintenance Manual
Page 12
ND-70926
(E),
Issue
3.0
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
: Fault Kind Number
Table 1-1 Fault Occurrence Kind Number
FAULT KIND NUMBER
FAULT CONTENT
01
System initialization
04
MP-FP/AP communication failure
08
FP/AP card down
09
Power failure
12
CS/ZT fault occurred
16
It is a day for periodic maintenance
20
DTI line failure
21
DCH/BRT/PRT D-Channel link connection failure
22
CCH/IPT link connection failure
24
[Australia Only]
Number of faulty trunks was more than predetermined number
25
Number of lockout stations was more than predetermined number
26
DLC card down
27
Synchronism of DPC missed
28
SMDR output buffer memory overflow
2B
CS/ZT fault occurred
Table 1-2 Fault Restoration Kind Number
FAULT KIND NUMBER
FAULT RESTORATION CONTENT
18
FP/AP card returned to normal condition
19
Power failure returned to normal condition
30
DTI line returned to normal condition
31
DCH/BRT/PRT D-Channel link connection returned to normal condition