CHAPTER 1 MAINTENANCE SERVICE FEATURES
Remote MAT
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 55
DESCRIPTION
DATA
Assign the outgoing access code and
called party number to Memory Slot
number allocated by CM71.
• Y = 0
(1) 000-299: Memory Slot No.
(2) Outgoing Access Code (Maximum of
four digits) +
+ Called Party No.
(Maximum of 26 digits)
Assign which kind of fault information is
stored into the fault information
memory, and which kind of alarm is
indicated.
• Y = 2
(1) See
.
Specify the alarm kind sent
automatically to the RMAT.
• Y = 3
(1) 00 : MJ alarm
01 : MN Alarm
02 : -- Alarm
(2) 0
: Send
1
: Not sent
Assign the office number sent to the
RMAT.
• Y = 4
(1) 00 : Office number sent to RMAT
(2) 00-999: Office No. 00-999
Specify the destination of fault
information as RMAT.
• Y = 4
(1) 01 : Destination of fault information
(2) 3
: IMX MAT + RMAT
7
: RMAT
CM72
A
CMEA
END
,