CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 23
04
MN
99/01/08 13:26
MP
MP-FP/AP communication failure
Overflow of data sending buffer to FP/AP. (Count = 10 FP/AP NO. = 04)
Data = (F0 0A 04 FF FF FF FF FF)
04
MN
99/01/08 13:26
MP
MP-FP/AP communication failure
Invalid data received from FP/AP. (Count = 96 FP/AP NO. = 07)
Data = (F1 60 07 FF FF FF FF FF)
04
MN
99/01/08 13:26
MP
MP-FP/AP communication failure
Invalid data received from FP/AP. (Count = 100 or more FP/AP NO. =
11)
Data = (F1 FF 0B FF FF FF FF FF)
08
MN
99/01/08 13:26
MP
FP/AP card down
(FP/AP NO. = 52)
Data = (F4 FF FF FF FF FF FF FF)
09
MJ
99/01/08 13:26
MP
Power failure
Power Failure Kind : AC input failure
Data = (00 01 02 FF FF FF FF FF)
09
MJ
99/01/08 13:26
MP
Power failure
Power Failure Kind : Fuse break
Data = (01 02 00 FF FF FF FF FF)
09
MJ
99/01/08 13:26
MP
Power failure
Power Failure Kind : PWR alarm
Data = (02 00 01 FF FF FF FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : Fault notice from CS/ZT (CS/ZT No. = 10)
Data = (00 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : CS/ZT initial failure (CS/ZT No. = 10)
Data = (01 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : CS/ZT condition read failure (CS/ZT No. = 10)
Data = (02 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : CS/ZT condition unmatch (CS/ZT No. = 10)
Data = (03 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : B-Ch condition unmatch (CS/ZT No. = 10)
Data = (04 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : SYS-ID upload failure (CS/ZT No. = 10)
Data = (05 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : SYS-ID download failure (CS/ZT No. = 10)
Data = (06 04 00 10 31 01 FF FF)
12
MN
99/01/08 13:27
MP
CS/ZT fault occurred
Fault kind : CS/ZT make busy failure (CS/ZT No. = 10)
Data = (07 04 00 10 31 FF FF FF)
Table 1-8 Examples of Fault Occurrence Display Using
MATWorX or MATWorX Studio (Continued)
Fault
Alarm
Date
CPU
Description
Содержание NEAX 2000IVS2
Страница 1: ...ND 70926 E ISSUE 3 PART OF STOCK 151969 Maintenance Manual FEBRUARY 2001 NECAmerica Inc...
Страница 152: ...NEAX2000 IVS2 Maintenance Manual Page 144 ND 70926 E Issue 3 0 This page is for your notes...
Страница 156: ...NEAX2000 IVS2 Maintenance Manual Page 148 ND 70926 E Issue 3 0 This page is for your notes...