3.
Troubleshooting Functional Failures in Operation
22
3.2
Problems on MC
3.2.1
"MC:--------" is displayed by entering the show system command
or the show mc command
When "MC:--------" is displayed by entering the
show system
command or the
show mc
command, follow the
instruction in "
Table 3-1: Problems and Actions When "MC:--------" is displayed
"
Table 3-1: Problems and Actions When "MC:--------" is displayed
3.2.2
"MC not found" is displayed when MC is accessed
When "MC not found" is displayed after the command for accessing to MC has been executed, follow the instruction in
"
Table 3-2: Problems and Actions When "MC not found" is displayed
."
Table 3-2: Problems and Actions When "MC not found" is displayed
No.
Failure
Troubleshooting Steps
1
Check to see ACC LED.
When ACC LED is lit in green, it indicates other process might be accessing to MC. After
the ACC LED lights off, execute the command again. If the ACC LED is not lit in green,
follow the instructions on No.2 and later.
2
Remove the MC then insert it.
After removing and inserting MC, execute the command again.
Confirm that no dust is attached on the MC or the memory card. If dust is adhere to them,
clean it with a dry cloth then insert the MC.
If a symptom still occurs after you have removed and inserted the MC for several times,
follow the instructions on No.3.
3
Replace the MC with a new one.
Replace the MC then execute the command again.
If a fault still occurs after the MC has been replaced, memory slot card might be broken. In
this case, replace the BCU
[IP8800/S6700]
, the CSU
[IP8800/S6600]
, the MSU
[IP8800/S6300]
, the system
[IP8800/S3600]
, or the system
[IP8800/S2400]
.
No.
Failure
Troubleshooting Steps
1
Check to see ACC LED.
When ACC LED is lit in green, it indicates other process might be accessing to MC. After
the ACC LED lights off, execute the command again. If ACC LED is not lit in green, follow
the instructions on No.2 and later.
2
Remove the MC then insert it.
After removing and inserting MC, execute the command again.
Check to see that any dust is not attached on the MC or the memory card. If dust is adhere
to them, clean it with a dry cloth then insert the MC.
If a symptom still occurs after you have removed and inserted the MC for several times,
follow the instructions on No.3.
3
Replace the MC with a new one.
Replace the MC then execute the command again. If a fault still occurs after the MC has
been replaced, memory slot card might be broken. In this case, replace the BCU
[IP8800/
S6700]
, the CSU
[IP8800/S6600]
, the MSU
[IP8800/S6300]
, or the system
[IP8800/
S3600] [IP8800/S2400]
.
Содержание IP8800/S2400 Series
Страница 10: ......
Страница 26: ......
Страница 62: ......
Страница 72: ......
Страница 190: ......
Страница 198: ......
Страница 215: ...153 6 Line Test 6 1 Testing Line ...
Страница 220: ......
Страница 221: ...159 7 Restarting the System This chapter describes the procedures for restarting the system 7 1 Restarting the System ...
Страница 227: ...165 Appendix Appendix A Contents of show tech support Command Display ...
Страница 248: ......