3.
Troubleshooting Functional Failures in Operation
31
Table 3-9: Troubleshooting for Failed 10BASE-T/100BASE-TX/1000BASE-T
No.
Troubleshooting Steps
Problem
Action
1
According to the failure
statistical information
displayed by the
show
interfaces
command,
check to see if the statistical
information below is
counted for the port. If
counted, see "Problem" and
"Action" columns.
•
Link down
Line quality is
degraded.
Check to see if the cable type is correct. For the fiber optics type, see
"Hardware Installation Guide."
Check to see if MDI-X is selected for pin mapping in the case of the
following:
•
The port setting is fixed.
•
The port setting is auto negations and auto MDIX function is
disabled.
Check the cable length. For the cable length, see "Hardware Installation
Guide."
Check to see if the cable is connected correctly.
Replace with the connection interface supported by this system. For the
connection interfaces supported by this system, see "Configuration
Settings."
Perform the line test on this system and confirm that there is no problem
in the receiving function. See the execution results of the
no test
interfaces
(Ethernet) command and follow the indicated actions.
For the test type to be specified, see "
6.1 Testing Line
."
2
According to the receiving
error statistical information
displayed by the
show
interfaces
command,
check to see if the statistical
information below is
counted for the port. If
counted, see "Problem" and
"Action" columns.
•
CRC errors
•
Symbol errors
Line quality is
degraded.
Check to see if the cable type is correct. For the fiber optics type, see
"Hardware Installation Guide."
Check to see if MDI-X is selected for pin mapping in the case of the
following:
•
The port setting is fixed.
•
The port setting is auto negations, and auto MDIX function is
disabled.
Check the cable length. For the cable length, see "Hardware Installation
Guide."
Check to see if the cable is connected correctly.
Replace with the connection interface supported by this system. For the
connection interfaces supported by this system, see "Configuration
Settings."
Perform the line test on this system and confirm that there is no problem
in the receiving function. See the execution results of the
no test
interfaces
command and follow the indicated actions. For the test
type to be specified, see "
6.1 Testing Line
."
3
According to the failure
statistical information
displayed by the
show
interface
s command,
check to see if the statistical
information below is
counted for the port. If
counted, see "Problem" and
"Action" columns.
•
MDI cross over changed
Pin mapping of the
cable is not correct.
Correct the pin mapping. For pin mapping, see the manual
"Configuration Settings."
4
Check the line type/line
speed for the port according
to the "Port detail"
information generated by the
show interfaces
command.
If the line type/line speed is
not correct, see the
"Problem" and "Action"
columns.
An incompatible
cable is used.
Check to see if the cable type is correct. For the fiber optics type, see
"Hardware Installation Guide."
The values set for
configuration
commands
speed
and
duplex
are
incompatible with
the target system.
Use the same values as the remote system in configuration commands
speed
and
duplex
.
Содержание IP8800/S2400 Series
Страница 10: ......
Страница 26: ......
Страница 62: ......
Страница 72: ......
Страница 190: ......
Страница 198: ......
Страница 215: ...153 6 Line Test 6 1 Testing Line ...
Страница 220: ......
Страница 221: ...159 7 Restarting the System This chapter describes the procedures for restarting the system 7 1 Restarting the System ...
Страница 227: ...165 Appendix Appendix A Contents of show tech support Command Display ...
Страница 248: ......