3.
Troubleshooting Functional Failures in Operation
28
Table 3-7: Check and Action for Port Status
(3) Checking statistical information
Enter the
show port statistics
command to check the number of sent/received packets and the number of
discarded packets on all ports installed on this system.
No.
Port Status
Problem
Action
1
active up
The port is operating normally.
None
2
active down
Line failure occurred in the port.
According to the log of the port displayed by the
show logging
command, see the corresponding part in manual "Message Log
Reference" and follow [Action] described.
3
inactive
The inactive state is set by one of the
following:
•
The
inactivate
command
•
Standby link of link aggregation
•
BPDU guard function of a spanning
tree
•
GSRP port-reset function
•
Failure detected by the IEEE802.3ah/
UDLD function
•
Port blocked by L2 loop detection
function
•
Port blocked by the storm control
function
•
If the inactive state is set by standby link function of link
aggregation, it is a normal operation and therefore do not set the
active state using the
activate
command. Check standby link
function using the
show channel-group
command with
"detail" parameter specified.
•
If the inactive state is set by the BPDU guard function of a
spanning tree, review the configuration of the opposite system.
Set up the configuration so that this system will not receive
BPDU. Using the
activate
command, set the port to the active
state. Check BPDU guard function using the
show
spanning-tree
command with "detail" parameter specified.
•
If the inactive state is set by the port reset function of GSRP, the
active state automatically restores. Since this is a normal
operation, do not set to the active state using the
activate
command.
•
If the inactive state is set by detection of one-way link failure or
L2 loop by IEEE802.3ah/UDLD function, see
"
3.18 Communication Failure on IEEE802.3ah/UDLD Function
."
After recovery from failure, use the
activate
command to
activate the port.
•
When ports blocked by L2 loop detection function are in inactive
status, change the configuration, which causes the loop. And then
enable the inactive port by using the
activate
command. At
this time, if
loop-detection auto-restore-time
has
been set by the configuration command, the ports will change
status to active status automatically.
•
If the inactive state is set by the storm control function, use the
activate
command to activate the port after LAN recovered
from the storm.
•
If you want to set the active in any other case, confirm that the
cable is connected to the port to be used and use the
activate
command to activate the port.
4
test
The port is in the line test by the
test
interfaces
command.
To restart communication, execute the
no test interfaces
command to stop the line test and activate the port with the
activate
command.
5
fault
Hardware of the port is faulty.
According to the log of the port displayed by the
show logging
command, see the corresponding part in manual "Message Log
Reference" and follow [Action] described.
6
initialize
The port is being initialized.
Wait until initialization completes.
7
disable or
locked
Configuration command
shutdown
is
set.
Confirm that the cable is connected to the port to be used and enter
configuration command
no shutdown
to activate the port.
Содержание IP8800/S2400 Series
Страница 10: ......
Страница 26: ......
Страница 62: ......
Страница 72: ......
Страница 190: ......
Страница 198: ......
Страница 215: ...153 6 Line Test 6 1 Testing Line ...
Страница 220: ......
Страница 221: ...159 7 Restarting the System This chapter describes the procedures for restarting the system 7 1 Restarting the System ...
Страница 227: ...165 Appendix Appendix A Contents of show tech support Command Display ...
Страница 248: ......