3.
Troubleshooting Functional Failures in Operation
111
When using SNMPv3
Execute the
show snmp-server
command to confirm that the information on the SNMP manager and trap has
been registered in the configuration for this system. If it is not correctly registered, execute the configuration
command below to set up the information on the SNMP manager and trap.
•
snmp-server engineID local
•
snmp-server view
•
snmp-server user
•
snmp-server group
•
snmp-server host
(config)# show snmp-server
snmp-server engineID local "engine-ID"
snmp-server group "v3group" v3 priv notify "view1"
snmp-server host 20.1.1.1 traps "v3user" version 3 priv snmp
snmp-server user "v3user" "v3group" v3 auth md5 "abc*_1234" priv des "xyz/
+6789"
snmp-server view "view1" 1.3.6.1 included
!
(config)#
In some SNMP manager systems, "ospf" or "bgp" traps issued by SNMPv2C or SNMPv3 may not be received. For
such systems, review the trap receiving settings on the SNMP manager in accordance with object ID for each trap
described in "MIB Reference."