i-Series Gateway
Page 6
G-6000G-SKE, Rev AA
&RQQHFWLRQV
The i-Series Gateway requires connections A through E as shown below.
Table 2. PBXtender Connections
Letter Label Cable
Type
Description
A
Console
DB-9
Connect to a PC for administration in two ways:
Direct serial connection to a PC.
Connect to a modem for remote access.
(See page 14 for modem installation and setup.)
Note: Set the COM port as follows; Baud rate: 9600,
Databits: 8, Parity: none, Stopbits: 1,
Software flow control: XON/XOFF
B
-
Power
Connect to a 120VAC outlet.
Connect as the last step. (See page 8.)
C Telephony
Interface
RJ 21
Wire to a punchdown block and then to the PBX.
(See Table 3, page 7.)
D
WAN1
DB 25, serial,
straight-through
Used for a synchronous or asynchronous-serial
connection. Connect to a TA, CSU/DSU, or other
network device.
Note: An RS-530 type cable or DB-25 to M34 cable
should be used for high-speed links to V.35 equipment.
E
LAN
RJ 45 Ethernet
Used for Telnet management or for connecting the unit
to the LAN for use in Voice over IP (RVP_IP)
applications.