1. POST Error Message
Express5800/R120f-2E, T120f Maintenance Guide
187
Chapter 3 Appendix
(1) Error messages
Error Message
Cause
Solution
8000
System variable is
corrupted.
Illegal setup information of
BIOS was detected.
Start BIOS Setup Utility (SETUP), and then
execute
Load Setup Defaults
and specify the
necessary settings.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
8001
Real time clock error
Real time clock error was
detected.
Start SETUP, and then specify the correct date
and time.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
8002
Check date and time settings
Incorrect date and time set on
real time clock was detected.
8003
System battery is dead -
Replace and run SETUP
The battery for storing system
settings is dead.
Contact your sales representative.
After the replacement, start SETUP, and then
specify the correct settings.
8005
Previous boot incomplete -
Default configuration used
The previous POST processing
did not finish.
Use SETUP to specify the correct settings.
8006
System configuration data
cleared by Jumper.
The setup utility settings were
cleared using the jumper.
Follow the steps described in
Chapter 1 (7.
Resetting and Clearing the Server).
Start SETUP, and then setup each item again.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
This error message also appears when lithium
battery is removed.
8007
SETUP Menu Password cleared
by Jumper.
The setup utility password was
cleared using the jumper.
8020
BIOS update error.
BIOS update failed.
Try BIOS update again.
If the same error is detected repeatedly, contact
your sales representative.
8021
Recovery jumper is set, but
recovery images is not
found.
Recovery jumper is set, but
recovery of BIOS failed.
Contact your sales representative.
8800
DXE_NB_ERROR
An error was detected during
initialization of chipset.
8801
DXE_NO_CON_IN
An error was detected during
initialization of console.
8802
DXE_NO_CON_OUT
8803
PEI_DXE_CORE_NOT_FOUND
A flash ROM is corrupt.
8804
PEI_DXEIPL_NOT_FOUND
8805
DXE_ARCH_PROTOCOL_NOT_AVA
ILABLE
8806
PEI_RESET_NOT_AVAILABLE
The system was not reset
correctly.
8807
DXE_RESET_NOT_AVAILABLE
Follow the steps described in
Chapter 1 (7.
Resetting and Clearing the Server).
Start SETUP, and then setup each item again.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
8808
DXE_FLASH_UPDATE_FAILED
The Flash ROM was not written
to correctly.
Contact your sales representative.
8830
PEI_RECOVERY_NO_CAPSULE
The Flash ROM was not
recovered correctly.
8831
PEI_RECOVERY_PPI_NOT_FOUN
D
8832
PEI_RECOVERY_FAILED
9000
Unsupported CPU detected
An unsupported CPU was
detected.
9001
Unsupported CPU detected on
CPU #1
9002
Unsupported CPU detected on
CPU #2
9021
Unsupported CPU Speed
detected on CPU #1
A CPU of which clock speed is
unsupported was detected.
9022
Unsupported CPU Speed
detected on CPU #2