1. POST Error Message
Express5800/R120f-2E, T120f Maintenance Guide
194
Chapter 3 Appendix
Error Message
Cause
Solution
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
Contact your sales representative.
C302
Hardware configuration
error.
Illegal hardware configuration
was detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected
when RAID controller is
installed.
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID controller is
inappropriate.
C310 Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
C320 Unmatched PSUs.
Unmatched power supply units
are configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption
exceeds the power output
capacity limit.
C322 No information for system
power consumption check.
No information is acquired in
checking system power
consumption.
C326
Configuration mismatch for
Advanced Fan control support
Advanced Fan Control feature
is disabled in this hardware
configuration.
Enable this feature in adequate configuration. Or,
run SETUP and select
Disabled
for the
Advanced Fan Control
. For the configuration
that allows this feature available, see
Chapter 1
(4.5 Internal View)
in
User's Guide
.
If the same error persists, contact your sales
representative.
C501 Intel(R) Node Manager is in
Recovery Mode.
Intel Node Manager is in
Recovery Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.