4-18 Configuring Your Server
Console Redirection Submenu
Option
Parameter
Description
Your Setting
BIOS Redirection
Port
[Disabled]
Serial Port A
Serial Port B
Enables or disables direct connection
from the management PC that uses
NEC ESMPRO Manager or hyper
terminal through the port specified
here.
Baud Rate
9600
[19.2K]
38.4K
57.6K
115.2K
Specify the baud rate used for the
interface with the remote console
connected.
Flow Control
None
Xon/Xoff
[CTS/RTS]
CTS/RTS+CD
Specify the flow control method.
Terminal Type
PC ANSI
[VT100+]
VT-UTF8
Specify the type of remote console.
Continue
Redirection after
POST
Disabled
[Enabled]
Specify whether to continue console
redirection feature after completion of
POST.
Remote Console
Reset
[Disabled]
Enabled
Specify whether to enable or disable
resetting by Escape command (Esc R)
sent from the remote console.
If the server is connected with the
management PC that uses NEC
ESMPRO Manager, this option is
always enabled even if "Disabled" is
specified here.
[ ]: Factory-set
Содержание Express5800/T120a-E N8100-1531F
Страница 34: ...2 4 General Description 2 5 inch Disk Model 1 Additional slot 1 Additional slot 2 4 5 6 7 8 2 3 9 10 ...
Страница 56: ...2 26 General Description This page is intentionally left blank ...
Страница 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Страница 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Страница 166: ...4 96 Configuring Your Server 6 Click Home at the lower left of the screen to go back to WebBIOS Top Menu ...
Страница 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Страница 259: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Страница 290: ...7 14 Maintenance This page is intentionally left blank ...
Страница 399: ...Upgrading Your Server 9 53 11 Bring down the lever to secure the CPU 12 Remove the protective cover from the heat sink ...
Страница 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Страница 428: ...A 4 Specifications This page is intentionally left blank ...
Страница 436: ...C 2 IRQ This page is intentionally left blank ...
Страница 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Страница 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...