Upgrading Your Server 9-45
Memory Mirroring
The memory mirroring feature writes the same data into two groups of DIMMs corresponding with
each other between memory channels (channels 0 and 1) to provide data redundancy.
IMPORTANT:
The memory mirroring feature uses channels 0 and 1.
In memory mirroring configuration, the memory channel 2 of each
CPU (CPU1-DIMM3/6, CPU2-DIMM3/6) is disabled.
Memory controller
Mirror set
#3
Mirror set
#1
Mirror set
#4
Mirror set
#2
Memory controller
NOTE:
The operating system only recognizes a half of the total
physical capacity.
The memory mirroring feature can be used under the following conditions:
Install memory devices on two memory sockets configuring a mirror set.
All the installed memory devices should have the same capacity.
Run SETUP (see Chapter 4), change parameters appropriately in the [Mirror] menu
selected as shown below, save the settings and exit from SETUP.
[Advanced]
→
[Memory Configuration]
→
[Memory RAS Mode]
→
[Mirror]
CH0
CH1
Data 1
Data 2
Data 3
Data 4
Data 1
Data 2
Data 3
Data 4
Example:
In 2-CPU
configuration
Содержание Express5800/T120a-E N8100-1531F
Страница 34: ...2 4 General Description 2 5 inch Disk Model 1 Additional slot 1 Additional slot 2 4 5 6 7 8 2 3 9 10 ...
Страница 56: ...2 26 General Description This page is intentionally left blank ...
Страница 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Страница 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Страница 166: ...4 96 Configuring Your Server 6 Click Home at the lower left of the screen to go back to WebBIOS Top Menu ...
Страница 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Страница 259: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Страница 290: ...7 14 Maintenance This page is intentionally left blank ...
Страница 399: ...Upgrading Your Server 9 53 11 Bring down the lever to secure the CPU 12 Remove the protective cover from the heat sink ...
Страница 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Страница 428: ...A 4 Specifications This page is intentionally left blank ...
Страница 436: ...C 2 IRQ This page is intentionally left blank ...
Страница 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Страница 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...