8-22 Troubleshooting
Error Messages on Virtual LCD
NEC EXPRESSSCOPE Engine 2 (Remote Management Controller) on your server board allows
you to monitor the server status on the Web browser.
POWER ON
ATTENTION
Virtual LCD
Status indicators
Message send from BIOS
Message send from BMC
Example:
Messages displayed on upper line (BIOS message)
On-screen message
Description
Action
XX BIOS Rev XXXX
POST in progress.
Wait until POST completes.
Prepare To Boot
POST completes normally.
Wait until Boot completes.
Mem Reconfigured
POST completes with memory degraded.
Mem Err Disable
A correctable memory error frequently
occurred.
CPU Reconfigured
POST completes with processor
degraded.
Memory C-Err XX
A correctable error frequently occurred.
Memory U-Err XX
An uncorrectable error has occurred.
PCI Bus SERR XX
A SERR has occurred in the PCI bus XX.
PCI Bus PERR XX
A PERR has occurred in the PCI bus XX.
Chipset Err XXXX
A chipset error occurred.
Contact your service
representative.
Messages displayed on lower line (BMC message)
On-screen message
Description
Action
Proc 1 VccpAlm
Proc 2 VccpAlm
BB P_Vtt Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +1.9vs Alm XX
BB +3.3v Alm XX
BB +3.3vs Alm XX
BB +5.0v Alm XX
BB +5vs Alm XX
BB +12v Alm XX
VBAT Alm XX
Voltage alarm occurred
XX=09: high voltage (alarm)
XX=02: low voltage (alarm)
XX=07: high voltage (warning)
XX=00: low voltage (warning)
Contact your service
representative.
Содержание Express5800/T120a-E N8100-1531F
Страница 34: ...2 4 General Description 2 5 inch Disk Model 1 Additional slot 1 Additional slot 2 4 5 6 7 8 2 3 9 10 ...
Страница 56: ...2 26 General Description This page is intentionally left blank ...
Страница 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Страница 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Страница 166: ...4 96 Configuring Your Server 6 Click Home at the lower left of the screen to go back to WebBIOS Top Menu ...
Страница 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Страница 259: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Страница 290: ...7 14 Maintenance This page is intentionally left blank ...
Страница 399: ...Upgrading Your Server 9 53 11 Bring down the lever to secure the CPU 12 Remove the protective cover from the heat sink ...
Страница 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Страница 428: ...A 4 Specifications This page is intentionally left blank ...
Страница 436: ...C 2 IRQ This page is intentionally left blank ...
Страница 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Страница 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...