8-14 Troubleshooting
Error
code
Error message
Recommended Action
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not write able.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0611
IDE configuration changed
0612
IDE configuration error - device disabled
Check IDE configuration.
0613
Com A configuration changed
0614
Com A config. error - device disabled
Check COM A configuration.
0615
Com B configuration changed
0616
Com B config. error - device disabled
Check COM B configuration.
0B22
Processors are installed out of order.
Request the maintenance to replace the
CPU.
0B28
Unsupported CPU detected on CPU socket
1.
0B29
Unsupported CPU detected on CPU socket
2.
Make sure that the server supports the
CPU. If you are not sure, contact your
service representative to request the
maintenance.
0B42
Resource Conflict
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
Contact your service representative.
0B60
CPU1_DIMM1 has been disabled
0B61
CPU1_DIMM2 has been disabled
0B62
CPU1_DIMM3 has been disabled
0B63
CPU1_DIMM4 has been disabled
0B64
CPU1_DIMM5 has been disabled
0B65
CPU1_DIMM6 has been disabled
Contact your service representative.
0B66
CPU2_DIMM1 has been disabled
0B67
CPU2_DIMM2 has been disabled
0B68
CPU2_DIMM3 has been disabled
0B69
CPU2_DIMM4 has been disabled
0B6A
CPU2_DIMM5 has been disabled
0B6B
CPU2_DIMM6 has been disabled
0B70
The error occurred during temperature
sensor reading.
Contact your service representative.
Содержание Express5800/T120a-E N8100-1531F
Страница 34: ...2 4 General Description 2 5 inch Disk Model 1 Additional slot 1 Additional slot 2 4 5 6 7 8 2 3 9 10 ...
Страница 56: ...2 26 General Description This page is intentionally left blank ...
Страница 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Страница 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Страница 166: ...4 96 Configuring Your Server 6 Click Home at the lower left of the screen to go back to WebBIOS Top Menu ...
Страница 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Страница 259: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Страница 290: ...7 14 Maintenance This page is intentionally left blank ...
Страница 399: ...Upgrading Your Server 9 53 11 Bring down the lever to secure the CPU 12 Remove the protective cover from the heat sink ...
Страница 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Страница 428: ...A 4 Specifications This page is intentionally left blank ...
Страница 436: ...C 2 IRQ This page is intentionally left blank ...
Страница 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Страница 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...