1. Installing Internal Optional Devices
Express5800/R120e-2E User’s Guide
128
Chapter 2 Preparations
1.22
Power Supply Unit
Your server can contain two power supply unit (one is factory-installed, and another is optional). The server
equipped with two hot-swap power supply units provides a redundant power configuration that ensures
continued operation of the system in the unlikely event one of the power supply units fails.
You can select a power supply unit appropriate your system configuration. See the table below.
16x 2.5-inch Drive Model
Model (Installed CPU)
Number of CPUs
Additional HDD
cage
Number of DIMM
Available power
supply unit
Not installed
–
800 W / 450 W
1 CPU
Installed – 800
W
Up to 6
800 W / 450 W
Not installed
7 or more
800 W
N8101-730F (E5-2403v2)
N8101-73
1
F (E5-2407v2)
N8101-732F (E5-2420v2)
N8101-733F (E5-2430v2)
N8101-734F (E5-2430Lv2)
2 CPUs
Installed – 800
W
Not installed
–
800 W / 450 W
1 CPU
Installed – 800
W
N8101-735F (E5-2440v2)
N8101-736F (E5-2470v2)
2 CPUs
–
–
800 W
26x 2.5-inch Drive Model/3.5-inch Drive Model
Number of CPUs
Additional HDD
cage
Number of DIMM
Available power
supply unit
– – –
800
W
1.22.1
Cold Redundant Feature
The server supports the feature to optimize power efficiency as described below:
•
Cold redundant feature can run the system with optimum power efficiency by raising operating efficiency
of primary power supply unit and lowering that of redundant power supply unit in redundant power
configuration.
•
If power efficiency of power units is not optimized due to system configuration, this feature is disabled
automaticlly.
Cold redundant feature can be used under the following conditions:
•
Two power supply units must be installed for redundant configuration.
•
Refer
to
Chapter 2 (1. System BIOS) in "Maintenance Guide"
, change parameters as shown below, save
the settings and exit from SETUP.
Server
→
Power Control Configuration
→
Cold Redundant Mode
→
Enabled
Run SETUP again, and check if the status of
Cold Redundant Mode
shows
Enabled
in
Server
menu.