21 Service Guide
4) Press Enter. The messages in Figure 5.4 appear.
A password is necessary to use the Administrator Menu.
Input the Maintenance Staff’s password.
Password->
Press the ESC key to Exit.
Figure 5.4
5) The password for maintenance persons is "CENVRAM." The password can be entered in either
uppercase or lowercase.
Enter the password. The window in Figure 5.5 appears.
Administrator Menu
Restore (after exchange of the Mother Board)
Customize Product/Chassis Information
Return to the previous menu
Figure 5.5
6) Select
[Restore (after exchange of the Mother Board)]
. The window in Figure 5.6 appears.
Restore(after exchange of the Mother Board)
Date Name
Device
Addr
Size
File Name
Restore
Product Information
SROM
00000098
0050
02ACprod.bin
Enabled
Chassis Information
SROM
00000010
0038
02ACchas.bin
Enabled
Internal Use Area
SROM
00000008
0008
02ACinte.bin
Enabled
Ambient Temp
Sensor Parameter
BMC
00000000
0010
02ACbmc1.bin
Enabled
Configuration Parameter
BMC
00000000
1000
02ACbmc2.bin
Enabled
GUID
BMC
00000000
0010
02ACguid.bin
Enabled
BIOS Parameter#1
RTC-S
0000000E
0072
02ACbio1.bin
Enabled
BIOS parameter#2
RTC-E
00000000
0080
02ACbio2.bin
Enabled
BIOS Parameter#3
BMCNVRAM
00000030
0050
02ACbio3.bin
Enabled
EXPRESSBUILDER Parameter
BMCNVRAM
00000000
0030
02ACexpb.bin
Enabled
Start to restore
Figure 5.6
Содержание EXPRESS5800/120Rd-1
Страница 1: ... EXPRESS5800 120Rd 1 S e r v i c e G u i d e ...
Страница 3: ...Revision Record Edition COMP Date Page Description 1 0 2003 1 16 First Edition ...
Страница 4: ...II Service Guide ...
Страница 18: ...XVI Service Guide ...
Страница 52: ...32 Service Guide 12 Appendix 12 1 Block Diagram System Block Diagram ...
Страница 53: ...33 Service Guide Power Block Diagram ...
Страница 67: ...47 Service Guide Figure 12 10 CRS Cable xx ...
Страница 68: ......
Страница 69: ......
Страница 70: ... ...