6 Service Guide
When the motherboard is replaced, the information that cannot be backed up is set to the default as
when the server was shipped. Thus, be sure to take notes of the information setting before
replacement of the mother board, and restore to the original setting in manual mode after the
replacement.
Information that can be backed up
!
Product information of the FRU information
(Model name, N code, FR, server serial number, etc.)
!
Chassis information (chassis designation number, etc.) of the FRU information
!
Settings of BMC
Information that cannot be backed up
!
Setting of BIOS SETUP
!
Setting of SCSI BIOS
!
Setting of optional boards
Information that does not need to be backed up
!
Package information (designation number, COMP, serial number, etc.) of the FRU information
!
On-board LAN MAC address
Starting various utilities
This function can start the following utilities, which are installed in the maintenance partition, through
EXPRESSBUILDER or the maintenance management tool:
!
System management function
!
System diagnostics
!
Maintenance partition setting