![NEC Express5800/120Ei Скачать руководство пользователя страница 82](http://html.mh-extra.com/html/nec/express5800-120ei/express5800-120ei_user-manual_251183082.webp)
4-14 Configuring Your Server
Server
Option
Parameter
Description
Your Setting
System
Management
–
System Management submenu is
displayed.
Console
Redirection
–
Console Redirection submenu is
displayed.
BMC LAN
Configuration
–
BMC LAN Configuration submenu is
displayed.
Event Log
Configuration
–
Event Log Configuration submenu is
displayed.
Assert NMI on
PERR
Disabled
[Enabled]
Specify whether to support PCI
PERR or not.
Assert NMI on
SERR
Disabled
[Enabled]
Specify whether to support PCI
SERR or not.
FRB-2 Policy
Disable FRB2 Timer
Disable BSP
Do Not Disable BSP
[Retry 3 Times]
Set the FRB level 2 timer.
Boot Monitoring
[Disabled]
5 Minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Specify whether to enable or disable
the boot monitoring function on
booting, or select the time limit for
timeout.
To use this function, install NEC
ESMPRO Agent. Set this item to
"Disabled" if the system is booted
from OS without installation of NEC
ESMPRO Agent.
Boot Monitoring
Policy
[Retry 3 Times]
Always Reset
Specify the processing at the
occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the
system is reset after the occurrence
of timeout and OS boot is retried up
to three times.
If [Always Reset] is selected, the
system is reset after the occurrence
of timeout and OS boot is retried
repeatedly.
* If no service partition exists in the
system, OS boot is retried
repeatedly from the system
partition.
Thermal Sensor
Disabled
[Enabled]
Specify whether to enable or disable
the thermal sensor monitoring
function. If a thermal error is
detected with this item being set to
"Enabled", the system stops at the
end of POST.
Содержание Express5800/120Ei
Страница 16: ...x This page is intentionally left blank ...
Страница 32: ...2 4 General Description 2 5 inch Disk Model 1 Additional slot 1 Additional slot 2 4 5 6 7 8 2 3 9 10 ...
Страница 126: ...4 58 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 137: ...Configuring Your Server 4 69 Use this menu to define several physical drives PD as a disk group DG ...
Страница 161: ...Configuring Your Server 4 93 3 Setting menu for VD 0 is displayed ...
Страница 213: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 238: ...7 12 Maintenance This page is intentionally left blank ...
Страница 356: ...C 2 IRQ This page is intentionally left blank ...
Страница 410: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 414: ...G 4 Product Configuration Record Table This page is intentionally left blank ...