Troubleshooting 8-25
Problems with Disk Array Configuration
Check the following if the server configuring a disk array does not operate properly or a utility does
not operate correctly. If a relevant item is found, follow the processing method.
Fail to install the OS:
T
Is the disk array controller configured?
→
Provide proper configuration for the disk array controller by using the LSI Logic
Software RAID Setup Utility.
Fail to start the OS:
T
Is the BIOS of the disk array controller changed?
→
Set the BIOS correctly by using the LSI Logic Software RAID Setup Utility.
T
Does POST recognize the disk array controller?
→
After making sure that the disk array controller is connected correctly, then power
on the server.
If the disk array controller is not recognized correctly despite correct connection,
the disk array controller may be failed. Contact your service representative.
Rebuild fails:
T
Is the capacity of the hard disk drive to be rebuilt sufficient?
→
The hard disk drive to be rebuilt should have the same capacity of the failed had
disk drive.
T
Is RAID0 configured?
→
RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, create the configuration data
again and initialize the hard disk drives. Then recover the data by using backup
data.
Auto rebuild fails:
T
Was a sufficient time taken for hot swap of hard disk drives?
→
To allow the auto rebuild to operate correctly, it should take 90 seconds or longer
for the interval between the removal of the failed hard disk drive and the
installation of a new hard disk drive.
T
Is configuration correct?
→
Check the setting of auto rebuild by using the LSI Logic Software RAID Setup
Utility. <Menus to check: Top menu - [Objects] - [Adapter] - [Auto Rebuild]>
A hard disk drive fails:
Contact your service representative.
Содержание Express 5800/120Eh N8100 SERIES
Страница 16: ...x This page is intentionally left blank...
Страница 32: ...2 4 General Description SATA Model 1 Additional slot 1 2 3 4 5 6 10 9 7 8 Additional slot 2 11...
Страница 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9...
Страница 52: ...2 24 General Description This page is intentionally left blank...
Страница 112: ...4 48 Configuring Your Server This page is intentionally left blank...
Страница 176: ...7 12 Maintenance This page is intentionally left blank...
Страница 234: ...9 28 Upgrading Your Server N8103 101 N8103 105 Black cable Red cable Red Black Black cable Red cable Red Black...
Страница 235: ...Upgrading Your Server 9 29 N8154 11 Additional HDD Cage Black cable Red cable Additional HDD cage Red Black...
Страница 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Страница 342: ...F 4 Product Configuration Record Table This page is intentionally left blank...