9-38 Upgrading Your Server
Removal
Remove the DIMM depending on the following procedure.
NOTES:
To remove the defected DIMM, check the error message appearing
in POST or NEC ESMPRO to identify the DIMM socket (group) in
which the defected DIMM is installed.
The server needs at least two DIMMs installed to operate.
1.
See the section "Preparing for Installation and Removal" described earlier to prepare.
2.
Open the levers at the both ends of the socket for the DIMM to be removed.
The lock is released to allow the DIMM to be removed.
3.
Remove the DIMM.
4.
Assemble the server.
5.
Turn on the power of the server. Make sure that no error message appears in the POST.
If POST displays an error message, take a note on the message and see the POST error
messages listed in Chapter 8.
6.
Run the BIOS SETUP and select [Advanced]
→
[Memory Configuration]
→
[Memory
Retest]
→
[Enabled] to clear the error information of the removed DIMM. (See Chapter 4
for details.)
7.
Select "Yes" for [Reset Configuration Data] on the [Advanced] menu.
This is required to update the hardware configuration information. See Chapter 4 for
details.
8.
If Windows Server 2003 is in use, set the paging file size to the recommended value or a
greater value. See Chapter 5 for details.
Содержание Express 5800/120Eh N8100 SERIES
Страница 16: ...x This page is intentionally left blank...
Страница 32: ...2 4 General Description SATA Model 1 Additional slot 1 2 3 4 5 6 10 9 7 8 Additional slot 2 11...
Страница 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9...
Страница 52: ...2 24 General Description This page is intentionally left blank...
Страница 112: ...4 48 Configuring Your Server This page is intentionally left blank...
Страница 176: ...7 12 Maintenance This page is intentionally left blank...
Страница 234: ...9 28 Upgrading Your Server N8103 101 N8103 105 Black cable Red cable Red Black Black cable Red cable Red Black...
Страница 235: ...Upgrading Your Server 9 29 N8154 11 Additional HDD Cage Black cable Red cable Additional HDD cage Red Black...
Страница 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Страница 342: ...F 4 Product Configuration Record Table This page is intentionally left blank...