8-8 Troubleshooting
POST Error Messages
When POST detects an error, it displays an error message on the display unit screen. The following
table lists error codes, error messages, and actions to take.
IMPORTANT:
Take a note on the messages displayed before
consulting with your service representative. Alarm messages are useful
information for maintenance.
Error
code
Error message
Recommended Action
0200
Failure Fixed Disk.
Contact your service representative.
0210
Stuck Key.
Disconnect the keyboard and connect it again.
0211
Keyboard error
Disconnect the keyboard and connect it again.
If the error cannot be corrected, contact your
service representative.
0213
Keyboard locked - Unlock key switch.
Release the lock of the key switch. If the error
cannot be corrected in spite of the release of
the lock, contact your service representative.
0220
Monitor type does not match CMOS - Run
SETUP.
Start the SETUP. If the error cannot be
corrected in spite of the start of SETUP,
contact your service representative.
0230
System RAM Failed at offset.
0231
Shadow Ram Failed at offset.
0232
Extended RAM Failed at address line.
Contact your service representative.
0250
System battery is dead - Replace and run
SETUP.
Contact your service representative to replace
the battery. (After restarting the computer, start
the SETUP to provide the setting again.)
0251
System CMOS checksum bad - Default
configuration used.
The default values have just been set. Start
the SETUP to provide the setting again. If the
error cannot be corrected, contact your
service representative.
0252
Password checksum bad - Passwords
cleared.
The password has just been cleared. Start the
SETUP to provide the setting again.
0260
System timer error.
0270
Real time clock error.
0271
Check date and time setting.
Start the SETUP to set the date and time
again. If the same error occurs successively in
spite of the resetting, contact your service
representative.
02D0
System cache error - Cache disabled.
The cache cannot be used. Contact your
service representative.
Содержание Express 5800/120Eh N8100 SERIES
Страница 16: ...x This page is intentionally left blank...
Страница 32: ...2 4 General Description SATA Model 1 Additional slot 1 2 3 4 5 6 10 9 7 8 Additional slot 2 11...
Страница 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9...
Страница 52: ...2 24 General Description This page is intentionally left blank...
Страница 112: ...4 48 Configuring Your Server This page is intentionally left blank...
Страница 176: ...7 12 Maintenance This page is intentionally left blank...
Страница 234: ...9 28 Upgrading Your Server N8103 101 N8103 105 Black cable Red cable Red Black Black cable Red cable Red Black...
Страница 235: ...Upgrading Your Server 9 29 N8154 11 Additional HDD Cage Black cable Red cable Additional HDD cage Red Black...
Страница 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Страница 342: ...F 4 Product Configuration Record Table This page is intentionally left blank...