8-10 Troubleshooting
Error
code
Error message
Recommended Action
0B92
Internal Use Area of BMC FRU corrupted.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service representative.
0B94
IPMB signal lines do not respond.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B95
BMC FRU device failure.
This is not a fatal error. Turn off the power
once and then on again to restart the server. If
the error cannot be corrected, contact your
service representative.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0B9A
Management controller not responding.
Update the RMC firmware. If the error cannot
be corrected, contact your service
representative.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service representative.
0BB0
SMBIOS – SROM data read error.
0BB1
SMBIOS – SROM data checksum bad.
Contact your service representative.
8100
Memory Error detected in DIMM group #1.
8101
Memory Error detected in DIMM group #2.
8102
Memory Error detected in DIMM group #3.
8103
Memory Error detected in DIMM group #4.
8104
Memory Error detected in DIMM group #5.
8105
Memory Error detected in DIMM group #6.
Contact your service representative to replace
the DIMM in the relevant group.
8160
Mismatch Processor Speed detected on
Processor 1.
8161
Mismatch Processor Speed detected on
Processor 2.
Contact your service representative.
None
Expansion ROM not initialized – PCI Mass
Storage Controller in slot xx (xx: slot number)
Disable initialization of the optional device
expansion ROM by using the BIOS SETUP
utility (see Chapter 4).
H/W Configuration of BMC is corrupted.
!! Update BMC F/W Configuration by
configuration tool !!
!! Refer to BMC configuration manual !!
Use the NEC EXPRESSBUILDER to
configure the optional remote management
card (see Chapter 6).
Содержание Express 5800/120Eh N8100 SERIES
Страница 16: ...x This page is intentionally left blank...
Страница 32: ...2 4 General Description SATA Model 1 Additional slot 1 2 3 4 5 6 10 9 7 8 Additional slot 2 11...
Страница 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9...
Страница 52: ...2 24 General Description This page is intentionally left blank...
Страница 112: ...4 48 Configuring Your Server This page is intentionally left blank...
Страница 176: ...7 12 Maintenance This page is intentionally left blank...
Страница 234: ...9 28 Upgrading Your Server N8103 101 N8103 105 Black cable Red cable Red Black Black cable Red cable Red Black...
Страница 235: ...Upgrading Your Server 9 29 N8154 11 Additional HDD Cage Black cable Red cable Additional HDD cage Red Black...
Страница 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank...
Страница 342: ...F 4 Product Configuration Record Table This page is intentionally left blank...