1. POST Error Message
Express5800/R120f-1E Maintenance Guide
189
Chapter 3 Appendix
Error Message
Cause
Solution
C301
SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
Contact your sales representative.
C302
Hardware configuration
error.
Illegal hardware configuration was
detected.
C303
FAN Structure ID command
error.
Illegal fan control was detected
when RAID Controller is installed.
C304
Necessary to update SDR
Version for new RAID Card.
SDR for RAID Controller is
inappropriate.
C310 Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
C320 Unmatched PSUs.
Unmatched power supply units are
configured.
C321 System power consumption is
out-of-range in PSUs.
System power consumption
exceeds the power output capacity
limit.
C322 No information for system
power consumption check.
No information is acquired in
checking system power
consumption.
C501 Intel(R) Node Manager is in
Recovery Mode.
Intel(R) Node Manager is is
Recovery Mode.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.