4-18 Configuring Your EcoPowerGateway
Option
Parameter
Description
Your Setting
Thermal Sensor
Disabled
[Enabled]
Specify whether the temperature sensor
monitoring feature is enabled or disabled. If a
thermal error is detected with this item being
set to "Enabled", the system stops at the end
of POST.
BMC IRQ
Disabled
[IRQ 11]
Specify whether to assign IRQ for BMC
(Baseboard Management Controller).
Post Error Pause Disabled
[Enabled]
Specify whether POST is aborted once at the
end of POST if an error occurs during the
execution of POST.
AC-LINK
Stay Off
[Last State]
Power On
Specify the AC-LINK feature. Shows the
system status when the AC power is supplied
again to the EcoPowerGateway. See the
table below.
Power ON Delay
Time (Sec)
[20] - 255
Specify the power-on delay time between 20
and 255 seconds. This option is available
only when "Power On" or "Last State" is
specified for AC LINK.
Platform Event
Filtering
Disabled
[Enabled]
Specify whether the Platform Event Filtering
feature of the Baseboard Management
Controller (BMC) is enabled or disabled.
[ ]: Factory-set
The table below shows the operation when the DC power to the EcoPowerGateway is turned off
once and then on again, depending on the setting of "AC-LINK".
When the DC power to the EcoPowerGateway is turned on, the standby power is supplied to the
Maintenance Card.
Setting of AC-LINK
System status before DC power off of
EcoPowerGateway
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (power of the Maintenance Card being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the Maintenance switch continuously at least four seconds. This forcibly turns off the
power.
Содержание EcoPowerGateway N8142-36F
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ... This page is intentionally left blank ...
Страница 16: ...vi This page is intentionally left blank ...
Страница 21: ...Notes on Using Your EcoPowerGateway 1 5 ...
Страница 23: ...Notes on Using Your EcoPowerGateway 1 7 ...
Страница 26: ...1 10 Notes on Using Your EcoPowerGateway ...
Страница 29: ...Notes on Using Your EcoPowerGateway 1 13 ...
Страница 38: ...1 22 Notes on Using Your EcoPowerGateway This page is intentionally left blank ...
Страница 56: ...2 18 General Description This page is intentionally left blank ...
Страница 136: ...A 2 Specifications This page is intentionally left blank ...