SMB Indication Handler Logging (Server)
B-18
Troubleshooting
SMB Indication Handler Logging (Server)
To assist in troubleshooting DMI event detection problems on the server, formatted DMI
indications, as well as other informational and/or error conditions, are written to log files.
On Unix, the SMB Indication Handler writes to the Server Manager Log File
/var/ldsm/log/sm_log_mmddyy. SMB Indication Handler log entries have a unique Error Tag of
the form 6609xxx07, where xxx is a message number. Two formatted indications logged by the
SMB Indication Handler on UNIX are shown below.
11/01/96 10:38:12:460 7989 660911707 dmiutils.c processindication INFO 0
0x21417:WARNING:Intel Corporation, Baseboard:Temperature Sensor:I/O Slot Area
Temperature Sensor:Upper Warning Threshold:
11/04/96 18:39:55:940 17796 660911707 dmiutils.c processSMBindication INFO 0
0x10401:Non-Critical:Physical System Description:NCR|Server Management Board|001
:SMB Status Change:Server Management Board:SMB Watchdog.
On Windows NT, SMB Indication Handler logging is enabled and configured by entries in the
SMBIH.INI file (located in the Windows NT directory). The same keyword entries, as supported
by the SMB Modem Transport (Console), with the exception of “LogWindow”, are supported by
the SMB Indication Handler. An example SMBIH.INI file appears below.
[Logging]
LogFile=“Smbih.log”
LogFileBak=“Smbih.log.bak”
LogFileMaxSize=1024000
LogLevel=6
The Intel Server Monitor Service must be restarted to make any changes to the SMBIH.INI active
(i.e., Stop and start the “Intel Server Monitor” from the Sevices dialog in the Control Panel).
Two formatted indications logged by the SMB Indication Handler on Windows NT are shown
below.
11/06/96 14:07:30:ERR-6:0:0x11101:Critical:Physical System Description: NCR|Cooling
Device Summary|001:Cooling Device Status Change:Chassis Management Board:Chassis
Monitor - Thermal:Critical:1
11/06/96 14:09:05:ERR-6:0:0x11201:OK:Physical System Description:NCR|UPS Battery
Summary|001:UPS Battery Status Change:Chassis Management Board: Chassis Monitor -
UPS:Normal:1
Содержание WorldMark 4300
Страница 1: ...BD20 1398 B000 12 97 WorldMark 4300 Server Management Product Manual Release 2 0...
Страница 6: ...Contents iv Table of Contents...
Страница 10: ...Preface viii Preface...
Страница 14: ...Monitored Controlled Attributes 1 4 Overview...
Страница 50: ...Working With Event Actions 2 36 User Interface...
Страница 66: ...Chassis Events A 10 SMB Event Code Tables...
Страница 96: ...LANDesk UNIX Server Troubleshooting B 30 Troubleshooting...
Страница 100: ...Index Index 4 WorldMark 4300 Server Management Product Manual...