Server Status Group
WorldMark 4300 Server Management Product Manual
2-15
Available Attributes
The following attributes are available on the Server Status group:
Attribute
Description
Power State
Power state of the server chassis which is based on the system voltages
versus the configured voltage thresholds and the state of the power supplies
Temperature State
Thermal state of the server chassis which is based on the system
temperature versus the configured temperature thresholds
Current Temperature
(I/O Slot Area)
Current temperature of the server chassis input/output slot area
(In-band only)
Current Temperature
(CPU/Mem Area)
Current temperature of the server chassis CPU and memory area
(In-band only)
Chassis State
State of the server chassis which is based on the combined power state,
thermal state, and the state of crucial chassis components
SMB Event Log
Last 5 critical events, from least recent to most recent, logged on the SMB
(Associated with the SMB itself)
This log contains SMB Firmware Event and SMB Hardware Event codes, as
represented in Appendix A of this manual
Single Byte Event Log
List of the single byte event values, from least recent to most recent, stored
in the SMB error log
(Associated with the power subsystem)
This log contains Chassis-specific Single Byte Event codes, as represented
in Appendix A of this manual
POST Codes
List of power on self test codes
(Out-of-band only)
Chassis Event Log
List of event codes, from least recent to most recent, from the SMB event log
(All events not associated with the SMB or power subsystem)
This log contains Chassis Event codes, as represented in Appendix A of this
manual
System Date
Current date at the server location
(In-band only)
System Time
Current time at the server location
(In-band only)
Current Voltage
(+5 Volt Sensor)
Current voltage reading from the +5 volt power supply line
(In-band only)
Current Voltage
(3.3 Volt Sensor)
Current voltage reading from the 3.3 volt power supply line
(In-band only)
Current Voltage
(+12 Volt Sensor)
Current voltage reading from the +12 volt power supply line
(In-band only)
Current Voltage
(-12 Volt Sensor)
Current voltage reading from the -12 volt power supply line
(In-band only)
Содержание WorldMark 4300
Страница 1: ...BD20 1398 B000 12 97 WorldMark 4300 Server Management Product Manual Release 2 0...
Страница 6: ...Contents iv Table of Contents...
Страница 10: ...Preface viii Preface...
Страница 14: ...Monitored Controlled Attributes 1 4 Overview...
Страница 50: ...Working With Event Actions 2 36 User Interface...
Страница 66: ...Chassis Events A 10 SMB Event Code Tables...
Страница 96: ...LANDesk UNIX Server Troubleshooting B 30 Troubleshooting...
Страница 100: ...Index Index 4 WorldMark 4300 Server Management Product Manual...