2-28 Chapter 2: Hardware Installation
Summary
If there is a touch screen calibration issue during or after installation,
take the following actions in the order listed:
1.
Recalibrate.
2.
If recalibration is unsuccessful after two attempts, then run the
Noise check to change the frequency.
3.
If you are still unable to calibrate, change the touch screen glass.
4.
The final step is to replace the Processor Board. If this corrects the
problem, then the old glass is probably OK to reuse.
Out-of-Box Failures
The RSG-Atlanta Customer Satisfaction Hotline will replace out-of-box
failed hard disks with identical, preloaded drives. Once a system is
successfully installed, all disk contents are the responsibility of the
customer. The customer is responsible for restoring operating system
software and/or customer-specific data onto replacement disks sent to
repair a failed or damaged disk in the field. NCR provides recovery
tools for the operating system and platform software.
Powering Down the Terminal
To power down the terminal, depress and hold the power off button
for 4-5 seconds.
Note:
If the unit is powered on and you pull the plug from the power
source and then plug it back in, the unit comes back on. If the unit is
powered off and you unplug it from its power source, then plug it back
in, the unit is still powered off.
Содержание 7460
Страница 1: ...NCR 7460 Retail Terminal Release 1 2 Hardware User s Guide B005 0000 1280 Issue D...
Страница 14: ...xii...
Страница 16: ...1 2 Chapter 1 Product Overview Serial Number Labels 7460 18821 18866 NCR Corp Model 7460 01 S N 35012156...
Страница 40: ...1 26 Chapter 1 Product Overview...
Страница 116: ...3 48 Chapter 3 BIOS Setup...
Страница 138: ...5 8 Chapter 5 BIOS Updating Procedures...
Страница 142: ...6 4 Chapter 6 NCR 7460 2x20 Customer Display Character Map...
Страница 144: ......
Страница 146: ...A 2 Appendix A Cables...
Страница 150: ......
Страница 153: ......