2-26 Chapter 2: Hardware Installation
Guidelines for Calibrating the Touch Screen
The following guidelines should be observed for calibrating the touch
screen.
•
Calibration should be done at time of installation
•
Recalibrate the touch screen when the system is installed at its final
location.
•
Recalibrate whenever the terminal is moved to a new location.
•
Recalibrate the touch screen anytime the system has been
disassembled for servicing.
•
Only use the Microcal (DOS) program or the Touchware Control
Panel (Windows) to calibrate the touch screen.
Microcal:
a.
Set the video resolution. Go to the
Tools
menu,
Video
. Select
800
x 600 256 colors
.
b.
Go to the
Tools
menu, select
Calibrate
.
Touchware Control Panel:
a.
Go to the
Calibrate
tab and press
Calibrate
.
Calibration Procedure
The calibration program looks at where your finger is when you lift it
off the screen, not where you touch it. Therefore, calibrate the screen as
follows:
1.
Touch the screen on the calibration target.
2.
Keep your finger on the screen and slide it to the center of the
target.
3.
Hold your finger firmly on the target for approximately two
seconds until directed to next target, then lift it off quickly.
Содержание 7460
Страница 1: ...NCR 7460 Retail Terminal Release 1 2 Hardware User s Guide B005 0000 1280 Issue D...
Страница 14: ...xii...
Страница 16: ...1 2 Chapter 1 Product Overview Serial Number Labels 7460 18821 18866 NCR Corp Model 7460 01 S N 35012156...
Страница 40: ...1 26 Chapter 1 Product Overview...
Страница 116: ...3 48 Chapter 3 BIOS Setup...
Страница 138: ...5 8 Chapter 5 BIOS Updating Procedures...
Страница 142: ...6 4 Chapter 6 NCR 7460 2x20 Customer Display Character Map...
Страница 144: ......
Страница 146: ...A 2 Appendix A Cables...
Страница 150: ......
Страница 153: ......