Model 7600 Family PWC User’s Manual
24
Unit On or Unit Off
When configured for
UNIT ON
, the scale will
allow you to switch between the selected
units of measure using the
UNITS
key.
Capacity (100, etc.)
Select the capacity of your scale.
Follow these steps to calibrate your scale. Refer
to Figure 2.
1. From normal weighing mode, move Switch 1
to the Menu Mode or OPEN position…
DIAG
is displayed. Press the
ZERO
key
until
CAL
is displayed. This stands for
calibration.
2. Press the UNITS key to start calibration…
LBS
or
1000g
(kg) is displayed.
3. Press the
ZERO
key to toggle between the
choices of units of measure (lb or kg). When
the choice you want is displayed, press the
UNITS
key to accept…
If
LBS
was chosen for calibration, the
scale will display the current setting.
Press the
ZERO
key to toggle between
SCALE
and
CLASSIFIER
. Calibrating as
SCALE
= .5 division rounding. Calibrating
as
CLASSIFIER
= .9 division rounding.
Press
UNITS
key to accept.
4. The current capacity is displayed. Press the
ZERO
key to toggle between scale capacity
selections. Press the
UNITS
key to accept…
That choice is accepted and
UNIT ON
or
UNIT OFF
is displayed.
Step -by-Step
Instructions for
CAL Mode