Model 7600 Family PWC User’s Manual
23
10. Press the
UNITS
key.
Parity selection is stored.
11. Press the
ZERO
key…
PROT
is displayed.
12. Press the
UNITS
key…
The current setting is displayed. Use the
ZERO
key to toggle between the four
choices:
NCI STD, NCI SMA, AS350D,
PS6L.
13. Press the
UNITS
key…
Protocol selection is stored.
14. When finished configuring your scale, press
the
ZERO
key until the display shows
DONE,
then press the
UNITS
key.
Or, move Switch 1 to CLOSED position for
normal weighing mode.
The calibration (CAL) mode menu lets you
calibrate your scale. The items in the calibration
menu are as follows:
Pounds/Kilograms (LB or 1000g)
Selects the unit of measure of your calibra-
tion test weights.
Scale or Classifier
When calibrating the scale for LB, you are
able to calibrate the unit as a scale or as a
classifier (weight classifier).
Calibration Mode
Calibration (CAL) Mode
Warning! Entering into
this mode can erase
the calibration already
saved. You need
approved calibration
weights to use
calibration mode
.
Note: If this procedure
is attempted without
proper calibration
weights applied, the
scale will abort the
process and retain the
original calibration
data.