Model 7600 Family PWC User’s Manual
19
Follow these steps to access the tests in the
DIAG
menu (Refer to Figure 2).
1. From normal weighing mode, move Switch 1
to the Menu mode or OPEN position.
DIAG
is displayed.
2. Press the
UNITS
key…
DISPLAY
is displayed.
3. Press the
UNITS
key to perform the display
test described earlier…
Display test is performed and shows
DISPLAY
after the test is completed.
4. Press the
ZERO
key…
RA
is displayed. This stands for the RAM
test.
5. Press the
UNITS
key to perform the RAM
test…
PASS
or
FAIL
is displayed briefly. If the
test fails, the unit may have a RAM
memory failure. Try the test a second
time and if
FAIL
is displayed, contact
your local Weigh-Tronix dealer for
service.
6. Press the
ZERO
key…
RO
is displayed. This stands for the
ROM test.
7. Press the
UNITS
key to perform the ROM
test…
PASS
or
FAIL
is displayed briefly. If the
test fails, the unit may have a program
memory failure. Try the test second time,
and if
FAIL
is displayed, contact your
local Weigh-Tronix dealer for service.
Step-by-Step Instruc-
tions for DIAG Mode
Press the
ZERO
key to
scroll through lists of
selections.
Press the
UNITS
key
to make a selection