Getting Started with MAXserver Access Servers
0038
134
Loading Problems
Refer to the following message descriptions for assistance in correcting
loading problems. Note that each <RETURN> generates a single message.
You must press <RETURN> every 5 - 10 seconds to receive updated
messages. Also, if the load process takes place very quickly, you might miss
some of the messages.
Problem: Not Connected to the Network
If the MAXserver is not connected to the network, you see one of the
following messages when you press <RETURN>:
AUTOMATIC NETWORK SELECTION: SEARCHING FOR FUNCTIONAL
NETWORK.
SEARCHING FOR FUNCTIONAL STANDARD ETHERNET NETWORK.
SEARCHING FOR FUNCTIONAL 10BASE-T ETHERNET NETWORK.
Problem: No response to a load request
Normal Process: A message similar to the following one is displayed while
the server is waiting for a response to the load request.
REQUESTING NETWORK LOAD SERVICE
If this message displays for more than 20 seconds after you type several
<RETURN>s, either the MAXserver is not configured on a load server, or it
cannot communicate with a load server.
If this message does not appear after you type several <RETURN>s, the
MAXserver unit could be at fault. Call NBase-Xyplex Customer Support. (In
the U.S., call 1-800-435-7997. For International calls, the number is 978-
952-4888).