Getting Started with MAXserver Access Servers
0038
156
LEDs
RUN, LAN, Flash Card Status, Console, Port
status and Diagnostic LEDs 1-10 (1620/1640)
LEDs 1-8 (1608B/1604)
Controls
Run/Reset push button switch
Dimensions
Height
Depth
Width
1640 and 1620 1608B and 1604
4.45 cm. (1.75 in.) 4.1 cm (1.62 in)
30.48 cm. (12 in.) 19.5 cm (7.7 in)
48.26 cm. (19 in.) 23.3 cm (9.9 in)
Weight
1640 and 1620 1608B and
1604
3.64 kg. (8 lbs.) 1.7 kg (3.8 lbs.
With ext. power supply)
Memory
4 MB DRAM, expandable to 8 MB with SIMM
memory modules.
Environment
10% to 90% humidity, noncondensing
Operating Temperature: 32° - 113° F (0 - 45°C)
Storage Temperature: -4 to 140° F ( -20 to 60°C)
Input Voltage
110 - 240 VAC 50 - 60 Hz (All MAXservers)
Power Requirements
1640
1620
1608B/1604
42W, 145Btu/hr 0.35 A at 110V (typ), 0.19A at
220V (typ)
32W, 110Btu/hr 0.27 A at 110V (typ), 0.15A at
220V (typ)
25W, 110Btu/hr 0.7A at 120V (typ), 0.3A at 220V
(typ)
Minimum Software
Requirements
Access Server Software, V5.3 or later for
MAXserver 1608A, 1620 and 1640. V6.0.3 or later
for MAXserver 1604 and 1608B.
Ethernet Interface
Ethernet/IEEE 802.3 Connection -- 10BASE-T or
AUI Transceiver