Getting Started with MAXserver Access Servers
0038
152
6.
Type 'M' and press <RETURN>. The unit displays a screen similar to
Figure 42.
Stored Configuration New Configuration
Load status messages: Enabled Enabled
Memory installed: 4 Megabytes 4 Megabytes
(Found 4 Megabytes)
(Type any key to continue)
Figure 42 - Sample Miscellaneous Configuration Display
The display indicates the amount of installed memory detected by the
MAXserver. If you have installed more memory than the display indicates,
try re-installing the SIMMs.
To exit the Miscellaneous Configuration display, press any key. The Display
Unit Configuration menu appears. Type 'X' at the "Enter menu selection"
prompt. This returns you to the main menu. Enter 'X' at the "Enter menu
selection" prompt. The MAXserver then proceeds to load its software.
Removing SIMMs
+
Before you remove SIMMs, you must configure the MAXserver
for less memory, using the Access server Configuration Menu.
If you fail to do so, the front panel lights will display an error
code the next time you try to initialize the unit.
Also, if you have enabled more software features than the
MAXserver can support with reduced memory, you will not be
able to reinitialize the unit after you remove the SIMMs. To
prevent this, configure the software for fewer features prior to
removing the SIMMs.