Getting Started with MAXserver Access Servers
0038
150
the memory installation by following these steps:
1.
Using a straightened paper clip, press the MAXserver RESET switch
once to enter reset mode. All lights on the front panel should illuminate.
2.
Press the RESET switch again, and hold the switch in. With the switch
held in, observe the port lights. The lights for Ports 9 and 10 should
illuminate on the MAXserver 1620 and 1640 (ports 7 and 8 on the
MAXserver 1604 and 1608 A/B). The port lights should then flash in
sequence from 1 to 10 (1 to 8 for MAXserver 1604 and 1608A/B) and then
back to 1 again. Port lights 8, 9 and 10 then illuminate (port lights 7 and
8 on the MAXserver 1604 and 1608A/B). When this sequence has
completed, release the RESET switch. The MAXserver performs the
standard self-test diagnostics. (The self test requires about 20 seconds to
complete.)
3.
When the RUN light flashes rapidly (indicating that the self test has
completed), autobaud any serial port by pressing RETURN a few times
at a terminal connected to the port. Once the MAXserver has selected a
port speed, it generates the following message:
ACCESS SERVER, TYPE 90, REV X
ETHERNET ADDRESS 00-DD-01-00-46-DD, PORT 1
CONFIGURATION IN PROGRESS. PLEASE WAIT.
4.
Type the password "ACCESS" (note that there is no prompt) and press
<RETURN>. The unit displays the menu shown in Figure 40: