TROUBLESHOOTING
The NH2001M are highly reliable units. However, if operating problems
occur, follow the troubleshooting steps below. If you find that the problem
persists, contact your local NBase representative.
1.
Symptom
None of the LEDs lights or blinks.
Cause
The module is defective.
Action
Replace the module.
2.
Symptom
The LINK LED does not light where:
Copper Port
a) The port is configured through software for 10Mbps, no
auto-speed sensing, with a connection to a 10Mbps PC adaptor.
b) The port is configured through software for 100Mbps, no
auto-speed sensing, with a connection to a 100Mbps PC adaptor.
c) The port is configured through software for 10Mbps, no
auto-speed sensing, with a connection to a 10Mbps hub.
d) The port is configured through software for 100Mbps, no
auto-speed sensing, with a connection to a 100Mbps hub.
Cause
a to d) Cable is not suitable or not connected securely.
Action
Check cable connections in all four cases.
Fiber Port
a) The NH2001MFO port is connected to the F/O port of any
100Mbps hub or switch.
Cause
a) F/O cable is not connected securely.
b) NH2001M unit is defective.
Action
a) Check cable connections.
b) Replace the NH2001MFO unit.
9
NH2001M
NBase Communications