1) CLEAR ALL
This will delete all programmed parameters and make all setting information
(including passwords) to the default settings. This does NOT include the master
keys which are stored in EPP.
2) CLEAR SETTING
This will delete all programmed parameters and make all information (including
passwords) to the default settings. This does NOT include the master keys which
are stored in EPP, denomination, journal data.
3) CLEAR JOURNAL
This will delete all journal data permanently
4) CLEAR TRANS. SEQUENCE NO.
This function will reset the journal sequence number to <0000>. This may be useful
if you switch processing or switch Terminal ID numbers and want to keep new
records.
5) CLEAR LOG
This will delete all logs permanently
<Note!>
Be careful when using these features (NVRAM clearing) – The initialized data can
NOT be recovered.