1. When the high pressure switch determines that the water pressure in-
side the tank is lower than the preset value, the system starts opera-
tiong.
2. The two last digits show the actual TDS value. The TDS value upper
limit is 100 ppm. If the value exceeds 100 ppm, the symbols 100 and
TDS flash one after another.
3. If the TDS value is higher than 50 and if the buzzer mode (E) is activ-
ated, a buzzer sounds.
4. The first digit shows “E” for the buzzer mode and P for the mute
mode, the last which can be activated by pressing the “MUTE” but-
ton.
5. Both the probe and the control unit regulate possible deviations in the
measuring range; do not combine the system with other devices.
6. The TDS measurement can easily be perturbed. Ensure that the
probe has been introduced to as sufficient depth inside the pipe to
guarantee accurate measuring results.
7. The presence of air bubbles inside the tubing system can influence
on the accuracy of the TDS measurement. Purge the pipes before
using the system.
(The high pressure pump works, the inlet valve opens, the outlet
valve closes.)
1. The system is activated and is rinsed for 30 seconds.
2. Cumulative water production for 6 hours; do not rinse the system dur-
ing that time, it will afterwards be rinsed automatically for 30 seconds.
3. Automatic rinsing for 30 seconds after the lack of water programme
having been finished.
4. The last two digits show the remaining back-flushing time, the clock
symbols flushes once per second.
5. The first digit shows “E” for the buzzer mode and “P” for the mute
mode, the last of which can be activated by pressing the “MUTE” but-
ton.
6. Rinse the system for 5 seconds before the water production and the
water tank filling.
(The high pressure pump works, the inlet valve opens, the outlet
valve closes.)
1. When the high pressure switch determines that the water pressure in-
side the water tank has reached to preset value, the water production
is stopped.
2. Shows the last measured TDS value during the water production or
rinsing. When the system does not produce any water, there is no
https://www.naturewater.eu