NatureWater 50808 Скачать руководство пользователя страница 2

The information contained in this document may alter at any time without previous notice. It is prohib-
ited to copy or spread any parts of this document in any way without prior written allowance. All rights
reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.

Send an e-mail to:

[email protected]

or use our contact form:

https://www.wiltec.de/contacts/

The most recent version of this manual in various languages can be found in our online shop via:

https://www.wiltec.de/docsearch

Our postal address is:

WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is:

WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously
or placing your order via the webshop.

E-mail: [email protected]
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

To return orders for exchange, repair or for other purposes, please use the following address. Atten -
tion! To allow for a smooth execution of your complaint or return, it is important to contact our cus -
tomer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler

E-mail: 

[email protected]

Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

https://www.naturewater.eu

Item 50808 and others

Page 2 

  

11 2020

-1

Содержание 50808

Страница 1: ...y depending on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning...

Страница 2: ...of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do yo...

Страница 3: ...00 times and filterable virus would be reduced in size more than 200 times Con sequently any super fine impurities harmful soluble solid bacteria and virus in water is blocked by the high density RO m...

Страница 4: ...vated car bon High density activated carbon Sixth filter stage Booster pump Purified water 4 way valve Flow out from goose neck water tap Pressure tank RO system structure A 3 way feed water connector...

Страница 5: ...is missing Usually it is between the third filter stage and the RO mem brane like it is in the technical drawing on the page before Please note that availability of a sixth filter stage is depending o...

Страница 6: ...our kitchen Please refer to the installation maps as follows If the RO unit would be suspended on the wall it should be fixed with two M6 swelling screws or two concrete steel nails according to the a...

Страница 7: ...er for usual washing Mark 3 Between the valve outlet M on water storage tank N and the Tee in front of post bacteriostatic activated carbon filter P with white plastic hose Mark 4 Between the goose ne...

Страница 8: ...e switch If the high pressure switch operates the system stops after 20 seconds If the key 6 Strong Washing is pressed the system purges for 20 seconds The LEDs 1 3 5 switched on mean that the system...

Страница 9: ...ly switched off in which case a warning buzzer is activated the display being as 5 If you press the button 6 for strong flushing Strong Washing the system is rinsed for 30 seconds RO controlbox 1 Digi...

Страница 10: ...lay being as 2 A buzzer indicates if feed water lacks or the water supply pressure is too low the display be ing as 3 After two hours of pure water preparation the system is rinsed for 30 seconds the...

Страница 11: ...ge the pipes before using the system The high pressure pump works the inlet valve opens the outlet valve closes 1 The system is activated and is rinsed for 30 seconds 2 Cumulative water production for...

Страница 12: ...e is higher than 100 ppm The controller setting limit is at 100 ppm precisely If the value is beyond this limit the controller cannot determine the value any longer and the OVA message is showed The n...

Страница 13: ...TDS test data may be a bit high please continue washing until the TDS test data normalizes C When you use the system for the first time the purified water is not drinkable until steps A and B are done...

Страница 14: ...for about 2 hours until the above operations is completed suc cessfully Clean the remaining contaminants and sediment inside the unit Check if the unit works normally and without water leakage 2 Do no...

Страница 15: ...ses the pump head to be filled with high pressure water that can cause a leak Improve the relevant com ponents No water purifying with pump normally working Maybe the RO membrane is blocked or the pum...

Страница 16: ...cle or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment...

Отзывы: