Rinsing the RO membrane

When the RO membrane purifies the water, there is impurity and bacteria left on the surface of the
membrane, which may affect the quality and volume of the purified water. Thus the RO membrane
must be cleaned periodically. In our system, the RO membrane is automatically washed. One may
manually wash the membrane by turning on the flush valve 

(L1) 

for 2–3 minutes once a week.

Note: 

In order to guarantee the efficient work of your system, please use the specified filters, provided

by the same vendor of the osmosis system.

Warning

1. Do not drink the water of first two tank contents; let it drain or use it for other purposes upon

installation. Test the RO unit for about 2 hours until the above operations is completed suc-
cessfully. Clean the remaining contaminants and sediment inside the unit. Check if the unit
works normally and without water leakage.

2. Do not take apart the parts of system. Any wrong operation may lead to water leakage and

system failure/damage.

3. Do not apply the system to purify hot water.
4. Do not place air valve discharged on the pressure tank.
5. To ensure the quality of purified water, please replace the first and the second filters after

10 months.

6. Please check the power supply and make sure it has a suitable voltage.

7.

Keep the RO unit away from sunshine.

8. When the system is not used for a long time, please turn off the power and shut off the ball

valve. 

9. Follow the initial operation before reusing the system after a long time of non-use.

https://www.naturewater.eu

Item 50808 and others

Page 14 

  

11 2020

-1

Содержание 50808

Страница 1: ...y depending on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning...

Страница 2: ...of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do yo...

Страница 3: ...00 times and filterable virus would be reduced in size more than 200 times Con sequently any super fine impurities harmful soluble solid bacteria and virus in water is blocked by the high density RO m...

Страница 4: ...vated car bon High density activated carbon Sixth filter stage Booster pump Purified water 4 way valve Flow out from goose neck water tap Pressure tank RO system structure A 3 way feed water connector...

Страница 5: ...is missing Usually it is between the third filter stage and the RO mem brane like it is in the technical drawing on the page before Please note that availability of a sixth filter stage is depending o...

Страница 6: ...our kitchen Please refer to the installation maps as follows If the RO unit would be suspended on the wall it should be fixed with two M6 swelling screws or two concrete steel nails according to the a...

Страница 7: ...er for usual washing Mark 3 Between the valve outlet M on water storage tank N and the Tee in front of post bacteriostatic activated carbon filter P with white plastic hose Mark 4 Between the goose ne...

Страница 8: ...e switch If the high pressure switch operates the system stops after 20 seconds If the key 6 Strong Washing is pressed the system purges for 20 seconds The LEDs 1 3 5 switched on mean that the system...

Страница 9: ...ly switched off in which case a warning buzzer is activated the display being as 5 If you press the button 6 for strong flushing Strong Washing the system is rinsed for 30 seconds RO controlbox 1 Digi...

Страница 10: ...lay being as 2 A buzzer indicates if feed water lacks or the water supply pressure is too low the display be ing as 3 After two hours of pure water preparation the system is rinsed for 30 seconds the...

Страница 11: ...ge the pipes before using the system The high pressure pump works the inlet valve opens the outlet valve closes 1 The system is activated and is rinsed for 30 seconds 2 Cumulative water production for...

Страница 12: ...e is higher than 100 ppm The controller setting limit is at 100 ppm precisely If the value is beyond this limit the controller cannot determine the value any longer and the OVA message is showed The n...

Страница 13: ...TDS test data may be a bit high please continue washing until the TDS test data normalizes C When you use the system for the first time the purified water is not drinkable until steps A and B are done...

Страница 14: ...for about 2 hours until the above operations is completed suc cessfully Clean the remaining contaminants and sediment inside the unit Check if the unit works normally and without water leakage 2 Do no...

Страница 15: ...ses the pump head to be filled with high pressure water that can cause a leak Improve the relevant com ponents No water purifying with pump normally working Maybe the RO membrane is blocked or the pum...

Страница 16: ...cle or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment...

Отзывы: