background image

To install the ball valve, fit a three way feed water connector 

(A) 

and place the ball valve 

(B)

on the three way feed water connector  

(A),

  then connect the water-tap with three way feed

water connector (Pic. 1, 7 and 8).

To install the RO membrane: screw off the cap of RO housing 

(J), 

put the one end with two

sealing rings of RO membrane 

(I) 

first into the RO housing, screw on the cap tight.

The goose-neck water-tap 

(Q) 

should be positioned for good aesthetics, function and conveni-

ence; it connects to the outlet fitting of the mineral ball filter by means of the white plastic
hose.

To install the plastic hose at following positions according to technological process. There are
marks numbered 1, 2, 3, 4, on the 

Reverse osmosis system layout and components

 

chart

(Pic. 1). 

You can also find these marks on the RO machine.

Mark 1:

 Between water tap and PPF filter 

(C) 

with white plastic hose.

Mark 2: 

Installing a drain tubing white plastic hose linking to the off let of drain restrictor and

flush valve. Put the drain tubing to sewer or connect with a container for usual washing.

Mark 3:

 Between the valve outlet 

(M) 

on water storage tank 

(N) 

and the Tee in front of post

bacteriostatic activated carbon filter 

(P) 

with white plastic hose.

Mark 4:

  Between the goose-neck water-tap  

(Q)  

and the post bacteriostatic activated carbon

filter or mineral ball filter if available.

Method of connecting plastic hose with fittings

Cut a plastic hose after measuring. 
Place the plastic hose into hexagon nut (Pic. 12).
Place white tube plug into the nozzle of plastic hose push the tube plug to the plastic hose end
by hand or tools (Pic. 12).
Place the plastic hose into the fittings (Pic. 12).
Screw on the hexagon nut tightly.

Method of connecting plastic hose with quick fittings (Pic. 10)

Cut a plastic hose after measuring.
Insert plastic hose deep into the quick fitting 

Method of disconnecting the plastic hose from the quick fittings (Pic. 11)

Remove the small part
Press the round part until it touches the main body of quick fitting.
Pull the plastic hose.

Power cord.
This system is equipped with a transformer which uses single-phase power supply of 220 V
(see transformer voltage). To use it, please plug the power cord of transformer into power
supply socket.

https://www.naturewater.eu

Item 50808 and others

Page 7 

  

11 2020

-1

Содержание 50808

Страница 1: ...y depending on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning...

Страница 2: ...of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do yo...

Страница 3: ...00 times and filterable virus would be reduced in size more than 200 times Con sequently any super fine impurities harmful soluble solid bacteria and virus in water is blocked by the high density RO m...

Страница 4: ...vated car bon High density activated carbon Sixth filter stage Booster pump Purified water 4 way valve Flow out from goose neck water tap Pressure tank RO system structure A 3 way feed water connector...

Страница 5: ...is missing Usually it is between the third filter stage and the RO mem brane like it is in the technical drawing on the page before Please note that availability of a sixth filter stage is depending o...

Страница 6: ...our kitchen Please refer to the installation maps as follows If the RO unit would be suspended on the wall it should be fixed with two M6 swelling screws or two concrete steel nails according to the a...

Страница 7: ...er for usual washing Mark 3 Between the valve outlet M on water storage tank N and the Tee in front of post bacteriostatic activated carbon filter P with white plastic hose Mark 4 Between the goose ne...

Страница 8: ...e switch If the high pressure switch operates the system stops after 20 seconds If the key 6 Strong Washing is pressed the system purges for 20 seconds The LEDs 1 3 5 switched on mean that the system...

Страница 9: ...ly switched off in which case a warning buzzer is activated the display being as 5 If you press the button 6 for strong flushing Strong Washing the system is rinsed for 30 seconds RO controlbox 1 Digi...

Страница 10: ...lay being as 2 A buzzer indicates if feed water lacks or the water supply pressure is too low the display be ing as 3 After two hours of pure water preparation the system is rinsed for 30 seconds the...

Страница 11: ...ge the pipes before using the system The high pressure pump works the inlet valve opens the outlet valve closes 1 The system is activated and is rinsed for 30 seconds 2 Cumulative water production for...

Страница 12: ...e is higher than 100 ppm The controller setting limit is at 100 ppm precisely If the value is beyond this limit the controller cannot determine the value any longer and the OVA message is showed The n...

Страница 13: ...TDS test data may be a bit high please continue washing until the TDS test data normalizes C When you use the system for the first time the purified water is not drinkable until steps A and B are done...

Страница 14: ...for about 2 hours until the above operations is completed suc cessfully Clean the remaining contaminants and sediment inside the unit Check if the unit works normally and without water leakage 2 Do no...

Страница 15: ...ses the pump head to be filled with high pressure water that can cause a leak Improve the relevant com ponents No water purifying with pump normally working Maybe the RO membrane is blocked or the pum...

Страница 16: ...cle or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment...

Отзывы: