background image

Introduction

Thank you for purchasing this quality product.

 To minimize the risk of injury we urge that our cli-

ents take some basic safety precautions when using this device. Please read the operation in-
structions carefully and make sure you have understood its content.

Keep these operation instructions safe.

General instructions

This manual describes the Usage of all our RO systems.
Please note that some parts of this manual are intended for certain systems. Usually the arrangement
of the filter stages is always the same. The number of filter stages depend on the model that you have
bought, between 1 and 6.

For RO-Systems without pump: If you use a pressure tank, the input water pressure should be higher
than 85 psi.

Operation principle

The RO system adopts U.S. high-tech reverse osmosis technology. This automatic reverse osmosis
system is composed of five filtration stages: First, the raw water is filtered by three pre positive cart-
ridges.
The 

first stage:

 The PPF cartridge removes suspended substance and other substances up to 5 mi-

cron in raw water.
The 

second stage:

 Granular activated carbon cartridge.

The 

third stage: 

High density activated carbon cartridge to remove odor, chlorine and its outgrowth in

raw water.
After above three stages of filtration, the filtered water is pushed into the 

fourth stage:

 the reverse os-

mosis (RO) membrane with a high-pressure pump.  Since the aperture of the RO membrane is only
0.0001 µ, bacteria and filterable virus can pass the RO membrane only if the bacteria would be re-
duced in size 4000 times, and filterable virus would be reduced in size more than 200 times. Con-
sequently, any super fine impurities, harmful soluble solid, bacteria and virus in water is blocked by the
high density RO membrane. The RO membrane can also filter other impurities and contamination from
the filtered water. The harmful substance is automatically removed by means of a waste water outlet.
The water filtered through the RO membrane enters a pressure tank for storage.
When the user turns on the goose-neck water-tap, the purified water will go through the 

fifth stage:

post positive bacteriostatic activated carbon filtration and
into the 

sixth stage: 

UV light to kill e. g. bacteria, virus, or mineral balls to re-introduce minerals into

the water.

The system controls the water purification process automatically. When the pressure of raw water is to
low or the water storage tank is full, the system will stop the purification machine automatically; when
the water pressure returns to the normal level, the purification machine will turn on automatically. 

The water purified by the RO system is pure drinking water without bacteria and impurities, rich in oxy-
gen, tasty and excellent for your health.

The different filter stages

Filter

Materials

Functions

Material life

in average

1

st

 stage

PP 5 micron

Un-dissolved   contaminants   removal,   i. e.
sand, silt, rust, etc.

About 10 months

2

nd

 stage

Activated carbon

Activated   carbon   germicidal   adhesion   re-
moval of chlorine, organic fertilizer, agricul-
tural chemical, insecticide

About 10 months

3

rd

 stage

Block carbon

Same as 2

nd

 stage, but re-filtration again

About 10 months

4

th

 stage

RO membrane

Heavy   metal   removal:   particles,   heavy About 2 years

https://www.naturewater.eu

Item 50808 and others

Page 3 

  

11 2020

-1

Содержание 50808

Страница 1: ...y depending on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning...

Страница 2: ...of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do yo...

Страница 3: ...00 times and filterable virus would be reduced in size more than 200 times Con sequently any super fine impurities harmful soluble solid bacteria and virus in water is blocked by the high density RO m...

Страница 4: ...vated car bon High density activated carbon Sixth filter stage Booster pump Purified water 4 way valve Flow out from goose neck water tap Pressure tank RO system structure A 3 way feed water connector...

Страница 5: ...is missing Usually it is between the third filter stage and the RO mem brane like it is in the technical drawing on the page before Please note that availability of a sixth filter stage is depending o...

Страница 6: ...our kitchen Please refer to the installation maps as follows If the RO unit would be suspended on the wall it should be fixed with two M6 swelling screws or two concrete steel nails according to the a...

Страница 7: ...er for usual washing Mark 3 Between the valve outlet M on water storage tank N and the Tee in front of post bacteriostatic activated carbon filter P with white plastic hose Mark 4 Between the goose ne...

Страница 8: ...e switch If the high pressure switch operates the system stops after 20 seconds If the key 6 Strong Washing is pressed the system purges for 20 seconds The LEDs 1 3 5 switched on mean that the system...

Страница 9: ...ly switched off in which case a warning buzzer is activated the display being as 5 If you press the button 6 for strong flushing Strong Washing the system is rinsed for 30 seconds RO controlbox 1 Digi...

Страница 10: ...lay being as 2 A buzzer indicates if feed water lacks or the water supply pressure is too low the display be ing as 3 After two hours of pure water preparation the system is rinsed for 30 seconds the...

Страница 11: ...ge the pipes before using the system The high pressure pump works the inlet valve opens the outlet valve closes 1 The system is activated and is rinsed for 30 seconds 2 Cumulative water production for...

Страница 12: ...e is higher than 100 ppm The controller setting limit is at 100 ppm precisely If the value is beyond this limit the controller cannot determine the value any longer and the OVA message is showed The n...

Страница 13: ...TDS test data may be a bit high please continue washing until the TDS test data normalizes C When you use the system for the first time the purified water is not drinkable until steps A and B are done...

Страница 14: ...for about 2 hours until the above operations is completed suc cessfully Clean the remaining contaminants and sediment inside the unit Check if the unit works normally and without water leakage 2 Do no...

Страница 15: ...ses the pump head to be filled with high pressure water that can cause a leak Improve the relevant com ponents No water purifying with pump normally working Maybe the RO membrane is blocked or the pum...

Страница 16: ...cle or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment...

Отзывы: